Fluke 113 vs Fluke 179: Which Multimeter Offers More Useful Features?
The Fluke 179 offers far more useful features for nearly every buyer: True RMS volts and amps to 10 A, a temperature probe, frequency to 100 kHz, high-impedance volts to 1000 V and resistance to 50 MΩ. The Fluke 113 has exactly one feature the 179 lacks, its VCHEK low-impedance voltage test that falls back to a continuity beep on a dead circuit, and that single trick is only worth choosing if proving power wiring live or dead is your entire workload. This Fluke 113 vs 179 comparison sorts every function by who actually uses it.
By the OhmSavvy Research Team ·
Disclosure: OhmSavvy earns a commission from qualifying Amazon purchases made through these links, at no extra cost to you. How we're funded.

Fluke 113
4.4★★★★☆A 6000-count utility meter built around VCHEK: one LoZ dial position that reads voltage and drops to continuity when the circuit is dead.

Fluke 179
4.7★★★★★Fluke's do-everything bench-and-field meter: CAT IV 600V, True RMS, temperature and a 6,000-count display with bar graph.
Specs side by side
| Fluke 113 | Fluke 179 | |
|---|---|---|
| Rating | 4.4★★★★☆ | 4.7★★★★★ |
| Accuracy | True RMS, ±(2.0% + 3) VCHEK volts | True RMS |
| Safety rating | CAT IV 600V (per Fluke) | CAT III 1000V / CAT IV 600V |
| Auto-ranging | Yes (manual override) | Yes (manual override) |
| Best for | Utility and ghost-voltage checks | Industrial maintenance, electronics, HVAC |
| Volts input | VCHEK LoZ only, about 3 kΩ | High impedance, no LoZ listed |
| Highest voltage | 600 V | 1000 V |
| DC volts accuracy | ±(2.0% + 3) | ±(0.09% + 2) |
| AC volts accuracy | ±(2.0% + 3), 45–500 Hz | ±(1.0% + 3) |
| Current | None (two jacks) | 0.01 mA to 10 A, no µA range |
| Resistance | 600 Ω to 60 kΩ | Up to 50 MΩ |
| Capacitance | 1,000 nF to 9,999 µF | Up to 10,000 µF (one Fluke table: 9,999 µF) |
| Frequency | Not stated | Up to 100 kHz |
| Temperature | None | −40 °C to 400 °C, 80BK probe included |
| Bar graph | Not stated | 33-segment analog bar graph |
| Hold / recording | Min/Max | Min/Max-Average, Auto Hold |
| Safety rating | CAT IV 600V per Fluke (Amazon: CAT III 600V / CAT IV 300V) | CAT IV 600V / CAT III 1000V |
| Battery | 9 V, about 300 h | 9 V, about 200 h |
| Weight | 404 g | 420 g |
| Warranty | Not stated for a new unit | Lifetime |
Specs checked against manufacturer documentation and official Amazon listings. Desk research, not bench testing. How we research.
Key differences
- →Volts: the 113 can only read voltage through VCHEK, a roughly 3 kΩ input that drains ghost voltage. The 179 has ordinary high-impedance volts to 1000 V and Fluke lists no LoZ mode for it.
- →Current: the 179 reads 0.01 mA steps up to 10 A. The 113 has two jacks and no current function of any kind.
- →Temperature and frequency: the 179 reads −40 °C to 400 °C with the included 80BK probe and frequency to 100 kHz. The 113 has neither, and Fluke states no frequency spec for it.
- →Resistance: the 179 reaches 50 MΩ against the 113's 60 kΩ, though on the kilohm ranges both carry the same ±(0.9% + 1) accuracy.
- →Identical or nearly so: both are rated CAT IV 600V by Fluke, both use 6,000-count backlit displays and a 9 V battery, and they weigh 404 g and 420 g.
- →Warranty: Fluke gives the 179 a lifetime warranty; it states no term for a new 113.
Counting features vs counting the ones you use
A feature only earns its keep if it answers a question you actually ask on the job. So rather than tally dial positions, the map below splits the two meters into three groups: what the 113 alone does, what the pair share, and what the 179 adds. The middle column is larger than most buyers expect, and the left column is a single idea.
Read the right column as a list of jobs. Amps covers motor loads, heater elements and the milliamp draw of a control board. Temperature covers bearings, breaker lugs, supply air and heat sinks. Frequency covers drive output checks and generator setups. High-impedance volts covers anything electronic. If none of those jobs appears in your week, the 179's advantage shrinks to accuracy, range and warranty; if two or more appear, the 113 isn't really a candidate.
The full function list, side by side
| Function | Fluke 113 | Fluke 179 | Who uses it |
|---|---|---|---|
| LoZ voltage test | Yes, VCHEK ≈3 kΩ | No | Electricians chasing phantom readings |
| Volts with auto continuity fallback | Yes | No | Utility live/dead verification |
| High-impedance volts | No | Yes, to 1000 V | Controls, sensors, electronics |
| Current | No | 0.01 mA to 10 A | HVAC, appliance, motor, automotive |
| Temperature | No | −40 °C to 400 °C | HVAC, maintenance, electronics |
| Frequency | Not stated | To 100 kHz | Drives, generators, power supplies |
| Resistance | To 60 kΩ | To 50 MΩ | Insulation leakage hints, sensors |
| Capacitance | 1,000 nF to 9,999 µF | To 10,000 µF | Motor run and start capacitors |
| Continuity | Beeps below 20 Ω | Not in the specs we cite | Everyone |
| Diode test | 2.000 V, ±(2.0% + 3) | Not in the specs we cite | Electronics |
| Hold and recording | Min/Max | Min/Max-Average, Auto Hold | Intermittent faults |
| Bar graph | Not stated | 33 segments | Watching a reading settle or drift |
Two rows on that list are blank for the 179 only because the Fluke spec lines we work from don't itemize continuity and diode figures for it, not because Fluke says they're absent. We'd rather mark them than guess. Every other cell comes from Fluke's spec tabs or the 113's official Amazon listing.
The 113's single exclusive: a voltmeter that can't be fooled
Pull a conductor off its breaker in a conduit shared with live circuits and a high-impedance meter like the 179 will often show tens of volts on it. That charge is coupled through the insulation and can't drive a load, but on the display it looks real. The 113 presents about 3 kΩ across its leads on VCHEK, which bleeds that coupled charge away so the reading collapses toward zero. Fluke lists no low-impedance mode for the 179, so its owner has to recognize the phantom some other way. Our explainer on voltage on a disconnected circuit covers why it happens.
The second half of VCHEK is what makes it quick. When no voltage is present, the same position turns into a continuity check that beeps below 20 Ω. Confirming that a feeder is dead and then confirming which conductor it is takes one dial setting instead of two.
That same low input is a handicap away from mains wiring. A 3 kΩ load drags down any weak source, and Fluke notes the 113's autorange needs at least 3 V DC before it registers, so thermostat signals, sensor outputs and logic rails are effectively off limits. The Fluke 113 vs Fluke 115 page works through that loading arithmetic, and Fluke 113 vs Fluke 117 looks at a meter that offers LoZ as a switchable option instead of the only way to read volts.
What the tighter accuracy means on real readings
Feature lists hide a quieter difference: how close each meter's voltage reading is guaranteed to be. Applying each published accuracy line to two common readings gives these worst-case bands. On a 6,000-count meter, 120 V sits on the 600.0 V range (one count is 0.1 V) and 24 V sits on the 60.00 V range (one count is 0.01 V).
The working: at 120 V the 113 allows 2.0% (2.4 V) plus 3 counts (0.3 V), so ±2.7 V; the 179 allows 1.0% (1.2 V) plus 3 counts, so ±1.5 V. At 24 V DC the 113 allows 0.48 V plus 0.03 V, about ±0.51 V; the 179 allows 0.09% (about 0.02 V) plus 2 counts (0.02 V), about ±0.04 V. For a live-or-dead decision, ±2.7 V on a 120 V circuit is irrelevant. For a voltage-drop calculation on a long branch circuit, or checking a 24 V control transformer against its nameplate, the 179's band is roughly a tenth as wide.
Resistance is the exception where the two match. On the 6 kΩ and 60 kΩ ranges both are specified at ±(0.9% + 1), so a thermistor or coil that fits inside 60 kΩ reads with equal confidence on either. Capacitance leans to the 179 at ±(1.2% + 2) against the 113's ±(1.9% + 2); on a 45 µF run capacitor the percentage part alone works out to about ±0.5 µF versus ±0.9 µF, a gap that rarely changes a pass-or-replace call.
Weight, battery and ratings: closer than the feature lists suggest
It's easy to assume the bigger feature set comes with a heavier, thirstier meter. The published numbers say otherwise. Fluke lists 404 g for the 113 and 420 g for the 179, a 16 g gap you won't feel on a belt. Both run on one 9 V battery; the 113 is rated about 300 hours and the 179 about 200 hours, so the simpler meter goes roughly half as long again between battery swaps.
The safety ratings also overlap. Fluke rates both meters CAT IV 600V, which covers service drops and the line side of a meter base. The 179 adds CAT III 1000V, useful on higher-voltage DC or industrial equipment inside a building, and the 113 doesn't go past 600 V at all. Where the 179 pulls clearly ahead off the spec sheet is the warranty: lifetime, against no published term for a new 113.
Which should you buy?
| Your situation | Better fit | Reason |
|---|---|---|
| Utility crew verifying de-energized lines | Fluke 113 | VCHEK reads live or dead, then beeps continuity |
| Electrician tracing circuits in crowded old conduit | Fluke 113 | LoZ input ignores coupled phantom voltage |
| Plant maintenance on motors and panels | Fluke 179 | Amps to 10 A, temperature, 1000 V and frequency |
| HVAC service calls | Fluke 179 | Current, the 80BK probe and capacitance; no µA range on either |
| Electronics and control boards | Fluke 179 | High-impedance volts and DC accuracy of ±(0.09% + 2) |
| Automotive and 12 V systems | Fluke 179 | The 113 can't read current and needs 3 V DC to autorange |
| One meter for every job in the van | Fluke 179 | It covers all but the LoZ test |
| Ghost voltage and amps in one tool | Neither: see the 117 | LoZ on a switch plus current ranges |
Skip the 113 if…
Skip the 179 if…
For the ladder below the 179, the Fluke 175 vs Fluke 179 comparison shows what each rung adds. If you want the 179's breadth plus a LoZ position, the Fluke 289 vs Fluke 179 page covers a logging meter with both, and the best multimeter for electricians guide lists the wider field.
Conflicting published specs to know about
Both meters carry at least one disagreement between sources. For the 113, Fluke's spec tab and the terminal markings give CAT IV 600V, while one Amazon bullet says CAT III 600V and CAT IV 300V; we follow Fluke. Its True RMS claim appears in the Amazon title and on the meter's front label but only in a footnote on Fluke's spec tab, and Fluke lists a 3-year term only for the reconditioned unit.
For the 179, Fluke's comparison table names µA as a function and gives 9,999 µF and a 400 °F temperature ceiling, while its detailed spec table gives 0.01 mA as the finest current step, 10,000 µF and 400 °C. We use the spec table, which means the 179 is not a flame-sensor meter; the Fluke 177 vs Fluke 179 page lays those rows out, and our microamp meter guide lists meters that do read a few microamps.
Safety: dead means tested, not assumed
Choose the Fluke 113 if…
- ✓Most of your readings answer one question: is this conductor live, dead or carrying a phantom charge?
- ✓You work in shared conduit and old buildings where induced voltage keeps fooling high-impedance meters
- ✓You never measure current, temperature or frequency and want a two-jack meter with nothing extra to set
Choose the Fluke 179 if…
- ✓You measure amps, from milliamp control signals up to 10 A motor and appliance loads
- ✓You check temperatures on bearings, ducts, breakers or heat sinks and want the 80BK probe in the box
- ✓You read sensors, drives or electronics where a low-impedance input would distort the result
The bottom line
For more useful features, buy the Fluke 179: it adds current, temperature, frequency, high-impedance volts to 1000 V, far wider resistance, tighter accuracy and a lifetime warranty while weighing only 16 g more. Pick the Fluke 113 only when your job is verifying power conductors live or dead, where its VCHEK low-impedance test and continuity fallback do something the 179 can't and the missing functions never come up.
Frequently asked questions
Does the Fluke 179 have a low-impedance (LoZ) mode like the 113?+
No. Fluke lists no LoZ position for the 179, so a disconnected conductor running beside live ones can show a coupled phantom voltage on its high-impedance input. The 113 reads voltage only through VCHEK, roughly 3 kΩ, which drains that charge. If you want both LoZ and current ranges, look at the Fluke 117 or the 289.
Can the Fluke 113 measure amps or temperature?+
Neither. The 113 has two input jacks and no current function, and Fluke lists no thermocouple input for it. The Fluke 179 reads current in 0.01 mA steps up to 10 A and temperature from −40 °C to 400 °C with the 80BK probe Fluke packs in the box. For either job, the 113 would need a second instrument alongside it.
Are the Fluke 113 and 179 both CAT IV rated?+
Yes, per Fluke. Both carry CAT IV 600V, and the 179 also lists CAT III 1000V. One bullet on the 113's Amazon listing quotes a lower CAT III 600V / CAT IV 300V rating, which conflicts with Fluke's spec tab and the meter's own markings. We follow Fluke. The 113 has no ranges above 600 V either way.
Which battery lasts longer, the Fluke 113 or 179?+
The 113. Fluke rates it at about 300 hours on a 9 V battery against about 200 hours for the 179, both figures without the backlight. That is roughly 50% more running time for the 113. Weight is almost identical: 404 g for the 113 and 420 g for the 179, so neither is noticeably easier to carry.
Can the Fluke 179 test a furnace flame sensor?+
Not by Fluke's detailed spec table, which gives 0.01 mA (10 µA) as the 179's finest current step. A flame-rod signal is typically only a few microamps. Fluke's comparison table on the same page mentions µA, so the sources conflict; we follow the spec table. The 113 has no current function at all, so neither suits that test.
Is the Fluke 113 good for electronics or automotive work?+
No. Every voltage reading passes through its 3 kΩ VCHEK input, which loads weak signals, and Fluke notes the autorange needs at least 3 V DC to register. It has no current function for drain tests and resistance stops at 60 kΩ. The 179's high-impedance volts, 0.01 mA current steps and 50 MΩ range suit both jobs much better.