COMPARISON · MULTIMETERS

Fluke 117 vs Fluke 87V

The Fluke 117 is the electrician's meter: CAT III 600V, VoltAlert non-contact detection and a LoZ AutoVolt position for ghost voltage. The Fluke 87V is the industrial troubleshooter: CAT IV 600V and CAT III 1000V, DC accuracy ten times tighter, microamp resolution, a 19,999-count mode, peak capture and a low-pass filter for motor drives. Buy the 117 for building wiring up to the panel; buy the 87V for service entrances, 1000V systems, drives and fine readings.

By the OhmSavvy Research Team ·

Disclosure: OhmSavvy earns a commission from qualifying Amazon purchases made through these links, at no extra cost to you. How we're funded.

Fluke 117 electrician's True RMS multimeter, front view
Best OverallHands-on Tested

Fluke 117

4.8★★★★★

The meter working electricians actually buy with their own money, not just the one brands push.

Fluke 87V industrial True RMS multimeter, front view
Best for ProfessionalsHands-on Tested

Fluke 87V

4.8★★★★★

The step-up pick for anyone who needs CAT IV protection and high-resolution readings daily.

Specs side by side

Fluke 117Fluke 87V
Rating4.8★★★★★4.8★★★★★
AccuracyTrue RMSTrue RMS
Safety ratingCAT III 600VCAT III 1000V / CAT IV 600V
Auto-ranging Yes Yes
Best forElectricians, serious hobbyistsIndustrial technicians, daily professional use
Display6,000 counts6,000 counts; 19,999 in high-res mode
Analog bar graph33 segments, 32 updates/s32 segments, 40 updates/s
Max voltage600 V AC/DC1000 V AC/DC
Basic DC volts accuracy±(0.5% + 2)±(0.05% + 1)
AC volts accuracy±(1.0% + 3), 45 to 500 Hz±(0.7% + 2)
Current6 A and 10 A; no mA or µA ranges10 A plus mA and µA (0.01 µA DC resolution)
ResistanceTo 40 MΩTo 50 MΩ
FrequencyTo 50 kHzTo 200 kHz, plus duty cycle
Temperature No-200 °C to 1090 °C (probe extra)
Non-contact voltageVoltAlert, Lo/Hi No
LoZ ghost-voltage inputYes (AutoVolt)Not listed by Fluke
VFD low-pass filter / peak captureNo / NoYes / 250 µs
Weight550 g355 g (624 g in holster)
Battery life400 h typical, no backlightAbout 400 h, alkaline, no backlight
Warranty3 yearsLifetime

Specs checked against manufacturer documentation and official Amazon listings. Both products hands-on tested by OhmSavvy. How we research.

Key differences

  • →Safety: the 87V is rated CAT IV 600V and CAT III 1000V; the 117 is CAT III 600V, so it isn't rated for the service drop or meter base.
  • →Precision: Fluke lists the 87V's basic DC volts accuracy at ±(0.05% + 1) against ±(0.5% + 2) on the 117, and the 87V adds a 19,999-count high-resolution mode.
  • →Low current: the 87V resolves down to 0.01 µA DC. The 117 starts at a 6 A range with 1 mA resolution, too coarse for flame sensors or standby drain.
  • →Electrician extras: only the 117 has VoltAlert non-contact detection and a LoZ AutoVolt position for ghost voltage. Fluke lists neither on the 87V.
  • →Drive work: only the 87V has a low-pass filter for variable-frequency drive outputs, 250 µs peak capture, duty cycle and temperature.
  • →Both have an analog bar graph (33 segments on the 117, 32 on the 87V), True RMS, a 9V battery rated about 400 hours, and up to 9,999 µF capacitance.

At a glance

Shared ground

True RMS, bar graph, 10 A current, capacitance, frequency, 400 h battery.

117 advantage

VoltAlert NCV and a LoZ AutoVolt position for ghost voltage on building wiring.

87V advantage

CAT IV 600V / CAT III 1000V and ten times tighter DC accuracy.

87V for drives

Low-pass filter, 250 µs peak capture, duty cycle and 200 kHz frequency.

87V for HVAC

Microamp resolution for flame sensors and a thermocouple input.

Verdict

Residential and commercial wiring: 117. Industrial, utility-side and drives: 87V.

OhmSavvy owns and has used both meters, which is why both carry the Hands-on Tested badge. The numbers on this page still come from Fluke's own product pages and specification tabs, not from our bench. For the full single-meter write-ups, read the Fluke 117 review and the Fluke 87V review.

Fluke 117 vs 87V spec by spec

Unlike the 115 and 117, which share one accuracy table, these two come from different Fluke families, so almost every line differs. The charts pick out the four numbers that change what you can safely and usefully measure.

Fluke 117
±(0.5% + 2)
Fluke 87V
±(0.05% + 1)
Basic DC volts accuracy, ±% of reading. Lower is better: the 87V is ten times tighter.
Fluke 117
6,000
Fluke 87V (high-res)
19,999
Highest display count. More counts means finer steps on the same range.
Fluke 117
50 kHz
Fluke 87V
200 kHz
Maximum frequency reading, kHz. The 87V reaches four times higher.
Fluke 117 (6 A range)
1 mA
Fluke 87V (DC µA)
0.01 µA

Bars use a logarithmic scale: each step is ten times the last.

Finest current step, on a log scale. The 117's 1 mA is 100,000 times coarser than the 87V's 0.01 µA.

To put the accuracy gap in numbers, take a 24.00 V DC control supply. Using Fluke's figures, the 117's ±(0.5% + 2) on its 60.00 V range allows 0.12 V plus 2 counts of 0.01 V, so ±0.14 V. The 87V's ±(0.05% + 1) allows 0.012 V plus one count, roughly ±0.02 V in its standard 6,000-count mode. For checking that a supply is "about 24 V" the 117 is plenty; for calibrating a 4-20 mA transmitter or trimming a reference, the 87V's margin is the reason it exists.

24.03V DC117 ±0.14 V
Illustrative only: a 24 V supply on the 117's 60.00 V range.
24.03V DC87V ±0.02 V
Illustrative only: the same supply on the 87V's 60.00 V range. Same digits, a much smaller error band.

The bar graph isn't an 87V exclusive

Older write-ups, including an earlier version of this page, credit only the 87V with an analog bar graph. Fluke's 117 spec tab lists a 33-segment bar graph refreshing 32 times a second; the 87V's has 32 segments and refreshes 40 times a second. Both let you watch a trend while you adjust something. What the 87V adds for fast events is the separate 250 µs peak-capture mode, which records a spike the bar graph would only flash.

CAT III 600V vs CAT IV 600V: where each meter is allowed

Measurement categories describe how much energy a transient can deliver at the point you probe. Close to the utility transformer, a lightning-induced surge or switching spike has very little wiring impedance to slow it down; at a receptacle on the far end of a branch circuit, it has a lot. The IEC 61010 impulse tables typically set a 6 kV test for CAT III 600V and 8 kV for CAT IV 600V and CAT III 1000V. Fluke says the 87V is designed to withstand spikes above 8,000 V.

CAT IVService drop, meter baseoutdoor feedersCAT IIIPanels, feeders,branch circuits, motorsCAT IIReceptacle loads,plug-in appliancesenergy available in a fault falls →Fluke 87V: CAT IV 600V and CAT III 1000VFluke 117: CAT III 600Vnot rated hereA higher category covers every category below it at the same voltage.
Measurement categories from the service entrance to the outlet, and how far each meter's rating reaches.

In practice, a residential or commercial electrician working inside panels and on branch circuits stays in CAT III, where the 117 is rated. Readings at the meter socket, the service conductors, an outdoor feeder or a utility-side disconnect are CAT IV work, and so is anything above 600 V, such as some solar strings and 690 V industrial distribution. That is where the 87V's rating, not its accuracy, decides the purchase.

Why drive technicians pick the 87V

A variable-frequency drive builds its output from fast PWM pulses. A True RMS meter reads all of that high-frequency content, so the voltage on the motor leads can look far higher than the fundamental the motor actually responds to. The 87V's low-pass filter, per Fluke, has its 3 dB point at 1 kHz, which strips the carrier and leaves a reading that tracks the drive's set frequency. The 117 has no filter, so its readings on drive outputs are hard to interpret. Add 200 kHz frequency, duty cycle and peak capture, and the 87V covers most of what a drive commissioning check needs short of a scope.

TaskFluke 117Fluke 87V
Receptacle and branch-circuit voltageYes, CAT III 600VYes
Ghost voltage on a shared conduitYes, LoZ AutoVoltLoad-test it yourself
First check for a live cordVoltAlert NCVSeparate NCV tester
Meter base or service conductorsNot ratedYes, CAT IV 600V
VFD output voltageUnfiltered, hard to readLow-pass filter
Furnace flame-sensor currentNo µA rangeYes, µA resolution
Thermocouple temperatureNoYes, probe extra
Catching a brief dropoutMin/Max/AvgMin/Max plus 250 µs peak

Fluke 117 vs 87V for electronics repair

On a repair bench the questions change. Nobody needs CAT IV to probe a 5 V rail, but you do care how small a change the meter can show, whether it reads a PWM signal's duty cycle, and whether it can measure the few milliamps or microamps a board draws in standby. Here the two Flukes are far apart, and the gap favors the 87V almost everywhere.

Bench functionFluke 117Fluke 87V
Finest DC volts step0.1 mV (600.0 mV range)10 µV (high-res mode)
Display counts6,0006,000; 19,999 high-res
FrequencyTo 50 kHz, ±(0.1% + 2)To 200 kHz, ±(0.005% + 1)
Duty cycleNot listedTo 99.9%
Capacitance1 nF to 9,999 µF, ±(1.9% + 2)To 9,999 µF
Diode test2.000 V, ±(0.9% + 2)Not stated in our sources
ResistanceTo 40 MΩ, ±(0.9% + 1)To 50 MΩ, ±(0.2% + 1)
Standby or sleep currentNo: 1 mA steps onlyYes: mA and µA, 0.01 µA DC
Low-pass filterNoYes, 3 dB at 1 kHz
Fluke 117
0.1 mV
Fluke 87V
10 µV

Bars use a logarithmic scale: each step is ten times the last.

Finest DC voltage step, log scale. The 87V's high-res mode resolves ten times finer.

What that means in practice: tracing a voltage drop across a PCB trace, a current-sense resistor or a connector pin often comes down to a few millivolts, which the 117's 0.1 mV step shows coarsely and the 87V's 10 µV step shows clearly. Duty cycle lets the 87V confirm that a fan controller or LED dimmer is actually modulating; the 117 can only give you the frequency. And because the 117's smallest current step is 1 mA on a 6 A range, it can't tell a healthy 200 µA sleep draw from a faulty 800 µA one, a job the 87V does in its µA position.

The 117 isn't useless on a bench. It reads capacitance from 1 nF, has a 2 V diode test and a continuity beeper below 20 Ω, and its True RMS AC input handles a mains-side power supply check. If you mostly replace fuses, check rails and swap obvious bad parts, it is enough. The low-pass filter is the one 87V feature that matters less here: it exists for drive outputs and rarely changes a bench reading. For meters chosen purely for boards, see our best multimeters for electronics repair.

Fluke 117 vs 87V for automotive diagnostics

A car is a 12 V DC system, so the 117's headline features, VoltAlert and the LoZ AutoVolt position, do little under the hood. What a technician needs is fast capture of intermittent faults, enough current capacity for a fused circuit, a duty-cycle reading for PWM-controlled parts and, on many jobs, temperature. Neither Fluke lists an RPM or dwell function in the specifications we cite, so tach work needs a dedicated automotive meter or a scan tool.

Under-hood jobFluke 117Fluke 87V
Voltage drop on a ground strapYes, 0.1 mV stepsYes, 10 µV in high-res
Wiggle test on a harnessMin/Max/Avg; catches 500 µs opensMin/Max plus 250 µs peak
Injector or PWM fan duty cycleNot listedYes, to 99.9%
Fused-circuit current10 A; 20 A for 30 s10 A; 20 A for 30 s
Parasitic battery drainCoarse, 1 mA stepsFine, mA and µA ranges
Coolant or intake temperatureNoYes, 80BK probe in box
RPM or dwellNot listedNot listed

The Min/Max difference is the one to understand. Both record minimum, maximum and average while you wiggle a connector or crank the engine, and the 117's continuity mode, per Fluke's 110 Series datasheet, flags opens and shorts as brief as 500 µs. The 87V adds a separate peak-capture mode that holds a 250 µs spike, which is how you catch an ignition-related transient or a relay that chatters for a moment.

Parasitic drain is where the 117 stops short. Many technicians use a figure around 50 mA as a rough after-sleep ceiling (check the vehicle maker's number). The 117 will show 0.050 A on its 6 A range, so it can follow a module settling from 35 mA to 22 mA, but only in whole milliamps, and it has no microamp range for motorcycles or other small batteries. The 87V reads the same drain on its mA input with finer steps. Its thermocouple input, -200 °C to 1090 °C at the meter (the 80BK probe in the box is rated -40 °C to 260 °C), also covers coolant and intake air checks. For tools built around RPM and dwell, see best multimeter for automotive.

Is the Fluke 87V worth the extra money?

The 87V sits in a clearly higher price tier than the 117. Amazon prices move, so we don't quote figures; instead, here is exactly what the step up buys and who actually uses each item. If you can't name two rows below that apply to your work, the 117 is the better buy.

What the 87V addsWho uses itWho can skip it
CAT IV 600V / CAT III 1000VService-entrance, solar, 690 V plantWork inside the panel
±(0.05% + 1) DC, 19,999 countsControls, instrument, bench techsGo/no-go voltage checks
µA and mA currentFlame rods, 4-20 mA, sleep drawLoad current via a clamp
Low-pass filter, 200 kHz, dutyDrive and PWM troubleshootingFixed-speed loads
250 µs peak captureIntermittent trips and dropoutsSteady-state readings
Temperature inputHVAC, process, automotiveWiring-only electricians
Lifetime vs 3-year warrantyAnyone keeping a meter for decadesShort-term or occasional use

Two things run the other way. The 117 keeps VoltAlert and LoZ, which the 87V doesn't list, so a residential electrician moving up to an 87V usually ends up buying a separate pen detector too. And the extra spend doesn't buy better AC accuracy where it counts for building wiring: on a 120 V circuit the two differ by about half a volt of allowance, which changes no decision. Our view, as owners of both: the 87V is worth it the day your work crosses into CAT IV locations, drives, microamps or calibration-grade DC, and not before.

Fluke 117 vs 87V: which should you buy?

You are…Better fitWhy
Residential electricianFluke 117CAT III covers panels and branch circuits; NCV and LoZ save time daily
Commercial electrician on 480 VFluke 117 or 87VBoth rated to 600 V; 87V if you also probe service gear
Industrial maintenance techFluke 87VCAT IV, 1000 V, drives, temperature and peak capture
Solar installer above 600 V DCFluke 87VThe 117 stops at 600 V
HVAC technicianFluke 87VMicroamps and temperature; the 117 has neither
Instrument or controls techFluke 87V0.05% DC accuracy and µA resolution for 4-20 mA loops
Homeowner or apprenticeFluke 117Lighter learning curve, built-in NCV, lower cost

If you need CAT IV but not the 87V's precision, the Fluke 87V vs Fluke 179 comparison covers the cheaper CAT IV option, and Fluke 117 vs Fluke 179 sets it against the 117. If the 117's extras are more than you need, see Fluke 115 vs Fluke 117.

Safety: the rating covers the whole setup

A meter's CAT rating only holds if the test leads carry the same or higher rating and are in good condition. Using a CAT III 600V meter at a meter base, or any meter with cracked or unrated leads, removes the protection the rating describes. Verify on a known live source before and after testing a circuit you expect to be dead. Work on utility-side equipment belongs to qualified electricians; if you aren't one, call one.

Choose the Fluke 117 if…

  • ✓Your work stops at the panel: branch circuits, receptacles, lighting and controls
  • ✓You want VoltAlert non-contact detection and a LoZ check for ghost voltage in one meter
  • ✓You don't need microamps, temperature, 1000V or a CAT IV rating

Choose the Fluke 87V if…

  • ✓You measure at the service entrance, meter base or outdoor feeders, where CAT IV applies
  • ✓You troubleshoot variable-frequency drives and want the low-pass filter and 250 µs peak capture
  • ✓You need microamps for flame sensors, temperature, or 19,999-count resolution on DC

The bottom line

Buy the Fluke 117 if you wire and troubleshoot buildings up to the panel: VoltAlert and LoZ solve everyday electrician problems and CAT III 600V covers the job. Buy the Fluke 87V if you work at the service entrance, above 600 V, on drives, or on anything that needs microamps, temperature or 0.05% DC accuracy. Many industrial electricians end up carrying both.

Frequently asked questions

Is the Fluke 87V more accurate than the Fluke 117?+

Yes, by a wide margin on DC. Fluke lists the 87V's basic DC volts accuracy at ±(0.05% + 1) and the 117's at ±(0.5% + 2), so the 87V is about ten times tighter. On AC volts the gap is smaller: ±(0.7% + 2) on the 87V against ±(1.0% + 3) on the 117 from 45 to 500 Hz.

Can the Fluke 117 be used on a service entrance?+

It isn't rated for it. The 117 is CAT III 600V, which covers distribution panels, feeders and branch circuits inside the building. The meter base, service drop and outdoor service conductors are CAT IV locations, where transients can carry more energy. For those, use a CAT IV 600V meter such as the Fluke 87V or Fluke 179.

Does the Fluke 87V have non-contact voltage detection?+

No. Fluke doesn't list VoltAlert or any non-contact sensor on the 87V; it is a feature of the 117 in the 110 Series. Most 87V owners carry a separate pen-style voltage detector for quick live checks, then confirm with the test leads before touching anything.

Can the Fluke 117 measure flame sensor microamps?+

No. Its lowest current range is 6.000 A with 1 mA resolution, and it has no mA or µA input. Furnace flame-sensor signals are usually a few microamps, so you need a meter with a µA range, such as the Fluke 87V, which resolves 0.01 µA DC, or the Fluke 116 in the same family as the 117.

Why is the Fluke 87V so much more expensive than the 117?+

It is a different class of instrument. You pay for the CAT IV 600V and CAT III 1000V rating, tenfold tighter DC accuracy, a 19,999-count mode, microamp and temperature ranges, a drive low-pass filter, peak capture and a lifetime warranty instead of three years. If none of that applies to your work, the 117 measures the rest just as reliably.

Which is better for electronics repair, the Fluke 117 or 87V?+

The 87V. Its 19,999-count mode resolves DC down to 10 µV, it reads duty cycle and frequency to 200 kHz, and its µA range measures standby current on a board. The 117 steps DC in 0.1 mV at best, stops at 50 kHz and has no current range finer than 1 mA, so it suits rail checks and fuse hunting rather than board-level fault finding.

Is the Fluke 117 or 87V better for automotive work?+

The 87V, if you diagnose rather than just check batteries. It adds duty cycle for injectors and PWM fans, 250 µs peak capture, temperature with the supplied 80BK probe, and mA/µA ranges for parasitic drain. Both carry 10 A (20 A for 30 s) and Min/Max. Neither lists RPM or dwell, so tach work needs an automotive meter.

Can the Fluke 117 measure parasitic battery drain?+

Roughly. On its 6 A range it reads in 1 mA steps, so a 50 mA drain shows as 0.050 A and you can see a module going to sleep. It can't resolve anything below a milliamp and has no µA range, so small-battery drains and fine module currents need a meter like the 87V. Wait for the vehicle's modules to go to sleep before you trust the reading.

Is the Fluke 87V worth it for a hobbyist or apprentice?+

Usually not as a first meter. Its value is CAT IV and 1000 V protection, calibration-grade DC accuracy, microamps, a drive filter and peak capture, which hobby and early apprentice work rarely needs. The 117 measures household circuits just as reliably for much less. Buy the 87V once your work moves into industrial, HVAC controls or instrumentation.

Related

More multimeter guides and reviews