Fluke 113 vs Fluke 117: Which Is Better for Electrical Testing?
For general electrical testing the Fluke 117 is the better meter, because it measures current, reads volts with or without a low-impedance load and adds VoltAlert non-contact detection. The Fluke 113 is not a cheaper 117. It is a verification tool: its single VCHEK position proves a conductor live, dead or carrying phantom voltage, Fluke rates it CAT IV 600V, and it has no amps at all. Buy it only when proving power wiring is the whole job.
By the OhmSavvy Research Team ·
Disclosure: OhmSavvy earns a commission from qualifying Amazon purchases made through these links, at no extra cost to you. How we're funded.

Fluke 113
4.4★★★★☆A 6000-count utility meter built around VCHEK: one LoZ dial position that reads voltage and drops to continuity when the circuit is dead.

Fluke 117
4.8★★★★★The meter working electricians actually buy with their own money, not just the one brands push.
Specs side by side
| Fluke 113 | Fluke 117 | |
|---|---|---|
| Rating | 4.4★★★★☆ | 4.8★★★★★ |
| Accuracy | True RMS, ±(2.0% + 3) VCHEK volts | True RMS |
| Safety rating | CAT IV 600V (per Fluke) | CAT III 600V |
| Auto-ranging | Yes (manual override) | Yes |
| Best for | Utility and ghost-voltage checks | Electricians, serious hobbyists |
| Volts positions | VCHEK LoZ only, about 3 kΩ | AutoVolt LoZ plus V AC (>5 MΩ) and V DC (>10 MΩ) |
| Volts accuracy | ±(2.0% + 3), DC and 45–500 Hz | DC ±(0.5% + 2); AC ±(1.0% + 3); LoZ ±(2.0% + 3) |
| Non-contact voltage | Not listed | VoltAlert, Lo and Hi sensitivity |
| Current | None (two jacks) | 6 A and 10 A AC/DC; 20 A for 30 s |
| Resistance | 600 Ω to 60 kΩ | 600 Ω to 40 MΩ |
| Capacitance | 1,000 nF to 9,999 µF | 1 nF to 9,999 µF |
| Frequency | Not stated | To 50 kHz (manual: 99.99 kHz) |
| Display | 6,000 counts; bar graph not stated | 6,000 counts + 33-segment bar graph |
| Min/Max | Min/Max | Min/Max/Avg |
| Safety rating | CAT IV 600V per Fluke (Amazon: CAT III 600V / CAT IV 300V) | CAT III 600V |
| Battery life | About 300 h (9 V) | About 400 h (9 V) |
| Weight | 404 g | 550 g |
| Warranty | Not stated for a new unit | 3 years |
Specs checked against manufacturer documentation and official Amazon listings. Fluke 117 is hands-on tested by OhmSavvy; the Fluke 113 assessment is desk research. How we research.
Key differences
- →Both meters have a low-impedance volts check of about 3 kΩ, but on the 113 it is the only way to read volts. The 117 also keeps normal high-impedance V AC and V DC positions.
- →The 117 measures current on 6 A and 10 A ranges through a fused A jack. The 113 has two jacks and no current function.
- →Only the 117 has VoltAlert non-contact detection, frequency and a 33-segment bar graph.
- →Fluke rates the 113 CAT IV 600V and the 117 CAT III 600V; one Amazon bullet for the 113 gives a lower CAT IV 300V figure.
- →The 113 is 146 g lighter (404 g against 550 g), but its resistance stops at 60 kΩ against the 117's 40 MΩ.
What the Fluke 113 is actually for
Most people who search for the 113 assume it sits below the 117 on a ladder of electrician's meters. It doesn't. Fluke sells it as a utility meter, and its dial is shaped around a single question asked over and over: is this conductor energized, and if not, is it the one I think it is? The 117 answers that question too, then goes on to measure what the circuit is doing.
113: the job
Prove live, dead or ghost; then confirm the conductor by continuity.
117: the job
Prove the circuit, then measure the load: amps, Hz, capacitors.
113: the edge
CAT IV 600V per Fluke, 404 g, one-position VCHEK.
117: the edge
Two volts inputs, a 10 A range and VoltAlert built in.
Shared
LoZ against phantom voltage, 6,000 counts, backlight, 9 V battery.
Our testing
The 117 is owner-tested; the 113 is desk research on Fluke specs.
The Fluke 117 is one of the meters the site owner has bought and used, so it carries our Hands-on Tested badge, and the Fluke 117 review goes into it in depth. The 113 has not been through that, so every statement about it below comes from Fluke's spec tab and the official Amazon listing. If you are choosing between the 113 and the general-purpose model with no LoZ at all, our Fluke 113 vs Fluke 115 page works through VCHEK and its circuit-loading trade-off in more detail.
Both have LoZ; only the 117 lets you switch it off
This is the difference that decides the pair, and spec tables bury it. Fluke lists a low-impedance input of about 3 kΩ on the 113's VCHEK position and on the 117's AutoVolt position, with the same ±(2.0% + 3) accuracy line. On a shared conduit full of abandoned conductors, the two behave alike: coupled voltage drains through the meter and a real supply stays put.
The 117 then has a second choice the 113 lacks. Turn one click to V AC or V DC and the input rises above 5 MΩ or 10 MΩ, so the meter barely disturbs what it reads. That matters on anything that isn't a stiff mains supply: a thermostat output, a doorbell transformer under load, a photocell or occupancy-sensor lead, a battery bank feeding a small inverter. On the 113 those readings all pass through 3 kΩ, and Fluke adds that its autorange won't register below 3 V DC, so low-voltage signals are largely out of reach.
LoZ also draws real current, and Fluke's 113 page warns that phase-to-earth LoZ checks can trip a GFCI or RCD. The same physics applies to the 117's AutoVolt position. The difference is that a 117 user can make the hot-to-ground check on V AC instead, while a 113 user has to test hot to neutral or reset the device afterward. Our explainer on why a GFCI keeps tripping covers the trip threshold.
Fluke 113 vs 117 comparison, function by function
| Function | Fluke 113 | Fluke 117 |
|---|---|---|
| Low-impedance volts | VCHEK, 6 / 60 / 600 V | AutoVolt, 600.0 V, AC/DC auto-select |
| High-impedance volts | No | 600 mV to 600 V AC and DC |
| Falls back to continuity when dead | Yes, on VCHEK | No; separate continuity position |
| Non-contact detection | Not listed | VoltAlert |
| Amps AC/DC | No | 6.000 A and 10.00 A |
| Resistance | To 60.00 kΩ | To 40.00 MΩ |
| Continuity | Beeps below 20 Ω, off above 250 Ω | Beeps below 20 Ω |
| Capacitance | 1,000 nF to 9,999 µF | 1 nF to 9,999 µF, ±(1.9% + 2) |
| Frequency | Not stated | To 50.00 kHz |
| Diode test | 2.000 V, ±(2.0% + 3) | Yes |
| Temperature | No | No (the 116 has it) |
| Recording | Min/Max | Min/Max/Avg |
The first chart shows the cost of a meter with no high-impedance position. On LoZ the two are equal, but the 117 can read DC four times more tightly by switching to V DC. On a 120.0 V reading, ±(2.0% + 3) allows about ±2.7 V, while the 117's V AC line of ±(1.0% + 3) allows about ±1.5 V. For proving a circuit live, either is plenty. For checking whether a supply sits inside a tolerance band, the 117 is the meter to trust.
The 113's real advantage: CAT IV 600V
Measurement category describes how much transient energy a meter is built to survive at a point in the supply. The closer you work to the utility, the larger the possible surge. Fluke lists the 113 under IEC 61010-2-033 at CAT IV 600V, and the meter body in the listing photo is printed the same. The 117 is rated CAT III 600V.
| Where you measure (typical) | Category | Fluke 113 | Fluke 117 |
|---|---|---|---|
| Service drop, meter base, line side of the main | CAT IV | Rated, per Fluke | Not rated |
| Distribution panel, feeders, busway | CAT III | Rated | Rated |
| Branch circuits, receptacles, fixed equipment | CAT III / II | Rated | Rated |
| Plug-in appliance on a cord | CAT II | Rated | Rated |
The zones above are the common reading of IEC 61010 categories, not a site survey, so check your own employer's rules. Note the source conflict: one bullet on the 113's Amazon listing gives CAT III 600V and CAT IV 300V, below Fluke's figure. We follow Fluke. If you need CAT IV and current together, the Fluke 117 vs Fluke 87V comparison covers a meter that has both.
A verification routine with each meter
Picture opening a disconnect to isolate a load and proving it dead before work. With the 113 the routine never leaves one dial position: check the meter on a known live source, test each conductor on the load side, and when nothing is there the same position confirms the conductor by continuity. With the 117 you can sweep the enclosure with VoltAlert before the leads come out, then use AutoVolt for the contact checks.
01
Prove the meter
Known live source first
02
Test each conductor
113 VCHEK or 117 AutoVolt
03
Near 0 V on LoZ
Phantom drained, not a feed
04
Prove the meter again
Live-dead-live, then work
The routine is the same on both, and that is the point: for verification alone, the 113 gives up nothing important. The gap opens the moment the job turns into diagnosis. A small motor that trips its overload needs a current reading, and a portable generator holding the wrong speed needs a frequency reading; the 117 takes both and the 113 lists neither. Our guide to voltage on a disconnected circuit explains why the LoZ step collapses a phantom reading.
Which should you buy?
| Situation | Better fit | Why |
|---|---|---|
| Utility or service-entrance verification | Fluke 113 | CAT IV 600V per Fluke; one-position live/dead check |
| Switching and isolation checks, clamp in the truck | Fluke 113 | VCHEK covers the meter's whole job |
| Residential or commercial service calls | Fluke 117 | Amps, high-impedance volts and VoltAlert |
| Apprentice's first meter | Fluke 117 | One tool for everything you'll be asked to measure |
| Tracing circuits in old buildings | Either | Both have a 3 kΩ LoZ check |
| Low-voltage controls and sensors | Fluke 117 | The 113 always loads the circuit |
| Motor, fan or generator troubleshooting | Fluke 117 | Current, frequency and capacitance from 1 nF |
| HVAC flame sensors or temperature | Neither | Those need the Fluke 116 |
For the electrician-side alternatives in the same family, see Fluke 114 vs Fluke 117 for the LoZ meter without amps, and Fluke 116 vs Fluke 117 for the HVAC model. The best multimeter for electricians guide ranks meters beyond Fluke's 110 Series.
Where the published specs disagree
Read these before you buy
Safety: a LoZ reading near zero is not permission to touch
Choose the Fluke 113 if…
- ✓Your job is proving conductors live or dead, not diagnosing the loads on them
- ✓You need Fluke's CAT IV 600V rating for work at the origin of the installation
- ✓You already carry a clamp meter for every current reading
Choose the Fluke 117 if…
- ✓You troubleshoot circuits and equipment, not just verify them
- ✓You want both a LoZ check and an ordinary high-impedance volts reading on one dial
- ✓You want current, frequency and non-contact detection without a second tool
The bottom line
The Fluke 117 is the better meter for electrical testing in general: it reads volts through either a LoZ or a high-impedance input, measures current to 10 A, and adds VoltAlert and frequency. The Fluke 113 is the right choice only for verification work, where its one-position VCHEK check, Fluke-stated CAT IV 600V rating and lighter body matter and a clamp meter handles every amp reading.
Frequently asked questions
What is the Fluke 113 used for?+
It is a utility meter for proving conductors live or dead. Its VCHEK position reads voltage through a low input impedance of about 3 kΩ and switches to a continuity check when nothing is there. It also reads resistance to 60 kΩ, capacitance and diodes, but it has no current ranges, so it is a verification tool rather than a troubleshooting meter.
Do the Fluke 113 and 117 both have LoZ?+
Yes. Fluke lists about 3 kΩ on the 113's VCHEK position and on the 117's AutoVolt position, with the same ±(2.0% + 3) accuracy. The difference is that the 113 has no other way to read volts, while the 117 also has normal V AC and V DC positions above 5 MΩ and 10 MΩ for circuits a low-impedance input would pull down.
Which is safer to use at the service entrance?+
The Fluke 113, on paper. Fluke rates it CAT IV 600V, which covers the meter base and service conductors, and the 117 is rated CAT III 600V, which stops at the distribution panel. One Amazon bullet for the 113 quotes CAT IV 300V instead, so confirm the rating printed on the meter you receive.
Can a Fluke 113 replace a Fluke 117 for an electrician?+
Only for part of the work. The 113 handles live-dead checks, ghost voltage and continuity, but it can't measure current, frequency or resistance above 60 kΩ, and it has no non-contact sensor. An electrician who also carries a clamp meter and a pen tester can manage with it; most service electricians are better served by the 117.
Does the Fluke 113 have non-contact voltage detection?+
Fluke's 113 spec tab lists no non-contact function, so plan on a separate pen tester. In this pair, only the 117 has it: VoltAlert, a sensor in the top edge with Lo and Hi sensitivity settings. A silent non-contact check is never proof that a conductor is dead, on either tool.
Can the Fluke 113 or 117 measure temperature?+
No. Neither meter lists a temperature function. Fluke's 110 Series datasheet gives the Type K thermocouple input to the Fluke 116 only, which also adds a 600.0 µA range for furnace flame sensors. If you need temperature and current on one meter, look outside the 110 Series at a model such as the Fluke 179.