COMPARISON · MULTIMETERS

Fluke 114 vs Fluke 117 for Residential Electricians

For a residential electrician, the Fluke 117 is the better all-day meter, and the Fluke 114 is a sound choice only if you already carry a pen tester and a clamp meter. Both share the feature that matters most in houses: AutoVolt, a low-impedance position that sorts ghost voltage on shared cable runs from a real feed. The 117 adds VoltAlert non-contact detection, 6A and 10A current, capacitance and frequency. Both are True RMS, CAT III 600V, 550 g and carry a 3-year warranty.

By the OhmSavvy Research Team ·

Disclosure: OhmSavvy earns a commission from qualifying Amazon purchases made through these links, at no extra cost to you. How we're funded.

Fluke 114 electrician's True RMS multimeter showing the AUTO-V LoZ position, front view
Best Go/No-Go Electrician Meter

Fluke 114

4.5★★★★★

A True RMS voltage-and-continuity meter with AutoVolt LoZ, made for quick go/no-go checks on 600 V circuits.

Fluke 117 electrician's True RMS multimeter with VoltAlert sensor, front view
Best OverallHands-on Tested

Fluke 117

4.8★★★★★

The meter working electricians actually buy with their own money, not just the one brands push.

Specs side by side

Fluke 114Fluke 117
Rating4.5★★★★★4.8★★★★★
AccuracyTrue RMS, ±(0.5% + 2) DC VTrue RMS
Safety ratingCAT III 600VCAT III 600V
Auto-rangingYes (manual override) Yes
Best forElectrician go/no-go voltage checksElectricians, serious hobbyists
AutoVolt LoZYes, 600.0 V, ±(2.0% + 3)Yes, about 3 kΩ, ±(2.0% + 3)
VoltAlert non-contact NoYes, Lo and Hi sensitivity
CurrentNone in Fluke's spec table6 A and 10 A AC/DC
CapacitanceNot listed1 nF to 9,999 µF
FrequencyNot listedTo 50 kHz (manual: 99.99 kHz)
Diode testNot listed Yes
DC / AC volts accuracy±(0.5% + 2) / ±(1.0% + 3)±(0.5% + 2) / ±(1.0% + 3)
ResistanceTo 40 MΩTo 40 MΩ
Safety ratingCAT III 600VCAT III 600V
Weight550 g (Amazon: 0.51 kg)550 g
Warranty3 years3 years

Specs checked against manufacturer documentation and official Amazon listings. Fluke 117 is hands-on tested by OhmSavvy; the Fluke 114 assessment is desk research. How we research.

Key differences

  • →Both have AutoVolt with a low-impedance input, so the ghost-voltage check on a shared cable run is the same on either meter.
  • →Only the 117 has VoltAlert, a non-contact sensor in its top edge that lights and beeps near a live AC conductor.
  • →Only the 117 measures current, on 6.000 A and 10.00 A AC and DC ranges through a fused A jack; the 114 has two jacks.
  • →Only the 117 lists capacitance, frequency and a diode test.
  • →Voltage and resistance accuracy, display, case, battery, CAT III 600V rating and 3-year warranty are the same.

The residential electrician's short answer

Shared: AutoVolt

LoZ volts on both, the house-wiring ghost-voltage fix.

117: VoltAlert

Sweep a box or cord for live AC without the leads.

117: amps

6 A and 10 A in series for fans, disposals, small motors.

117: capacitance

Ceiling fan and condenser run capacitors in µF.

114: simplicity

Fewer positions, nothing to set wrong on a quick check.

Verdict

Service work: 117. New-construction installs: 114 is enough.

The Fluke 117 is one of the meters the OhmSavvy team has bought and tested, and it carries our Hands-on Tested badge; the 114 has not been through that, so its details come from Fluke's spec tab and the official Amazon listing. Our Fluke 117 review covers the larger meter in depth.

Fluke 114 vs 117 spec by spec

The 114 is the 117 with the load-side functions removed. Fluke kept every voltage, resistance and continuity line identical and dropped the A jack, capacitance, frequency, diode test and the VoltAlert sensor.

SpecFluke 114Fluke 117
Display6,000 counts, 33-segment bar graph6,000 counts, 33-segment bar graph
True RMSAC voltsAC volts and AC amps
DC volts600 mV to 600 V, ±(0.5% + 2)600 mV to 600 V, ±(0.5% + 2)
AC volts, 45–500 Hz±(1.0% + 3)±(1.0% + 3)
AutoVolt LoZ600.0 V, ±(2.0% + 3)600.0 V, ±(2.0% + 3)
VoltAlertNoLo and Hi sensitivity
CurrentNone listed6.000 A / 10.00 A; 20 A for 30 s
Resistance600 Ω to 40 MΩ600 Ω to 40 MΩ
ContinuityBeeps below 20 ΩBeeps below 20 Ω
CapacitanceNot listed1 nF to 9,999 µF
FrequencyNot listedTo 50.00 kHz
Min/Max/AvgYes, with elapsed timeYes
SafetyCAT III 600VCAT III 600V
Battery9 V, 400 h typical9 V, 400 h typical
Fluke 114
5 of 10
Fluke 117
10 of 10
Residential tasks from the table further down that each meter can do on its own, out of 10.
100 W bath fan
0.8 A
600 W disposal
5.0 A
1,200 W microwave
10.0 A
1,500 W heater
12.5 A
Current drawn by example 120 V loads (watts ÷ 120). The 117's top range is 10.00 A; the 114 can't measure any of them.

The wattages in the second chart are examples, not nameplate data; read the label on the actual appliance. The arithmetic shows where the 117's in-series current input stops being useful: a 1,200 W load sits right at its 10.00 A ceiling, and a 1,500 W heater needs the 20 A allowance, which Fluke limits to 30 seconds.

Checking a receptacle with either meter

The bread-and-butter residential check is the same on both: three probe pairs at the receptacle. On a correctly wired 120 V circuit you expect roughly 120 V hot to neutral, roughly 120 V hot to ground and close to zero neutral to ground, rising by a few volts when the circuit is loaded. Utility voltage normally lands within about 5% of nominal, so 114 to 126 V is a typical healthy range.

hotneutralgroundHot to neutral≈120 V (nominal)Hot to ground≈120 V; LoZ may trip a GFCINeutral to groundnear 0 V; a few volts under loadBoth meters make these checks identically with the leads.
The three receptacle checks and nominal readings. Values are standard US 120 V figures, not measurements.

One caution applies to AutoVolt on both meters. A low-impedance input draws far more current than a normal volts position, and Fluke's documentation for its 113 LoZ meter warns that phase-to-earth LoZ readings can trip a GFCI or RCD. The same principle applies here, so on a GFCI-protected receptacle make the hot-to-ground check on the normal V AC position. For receptacles that refuse to reset, see our guide to testing a GFCI outlet that won't reset.

Ghost voltage in houses: a draw

Residential wiring produces phantom readings constantly. A three-way traveler, a switch leg left disconnected, or an abandoned circuit in the same cable as a live one all couple voltage through the insulation. A 10 MΩ volts input shows 30, 50 or more volts on a conductor that can't light a lamp. Both the 114 and 117 handle this the same way: switch to AUTO-V LoZ, and a coupled phantom collapses while a real feed holds. Our explainer on voltage on a disconnected circuit covers why.

  1. 01

    Odd reading on V AC

    e.g. 40 V on a switch leg

  2. 02

    Switch to AUTO-V LoZ

    Same on 114 and 117

  3. 03

    Reading collapses

    Coupled phantom, not a feed

  4. 04

    Reading holds

    Real backfeed: find the source

This is why the 114 is still a serious electrician's meter rather than a stripped-down one. On a remodel where old and new cable share a box, the LoZ check is the one you reach for most, and you get it on either meter.

VoltAlert on service calls

The 117's VoltAlert sensor is in the top edge of the meter. Hold it near a cord, a receptacle face or a bundle of conductors in an open box and it lights a red LED and beeps when it senses AC. Fluke's manual gives two settings: Lo for flush receptacles, power strips and cords, and Hi for recessed sockets and bare wire down to 24 V. On a service call that means you can find which of four cables in a crowded box is still hot before the leads come out.

The 114 has no sensor, so a 114 user carries a separate non-contact pen, which most residential electricians already own. If yours lives in your shirt pocket anyway, VoltAlert is a convenience, not a reason to spend more. If you would rather carry one tool, it is a real gain.

Residential tasks: which meter does what

Residential taskFluke 114Fluke 117
Outlet hot / neutral / ground readingsYesYes
Ghost voltage on a switch leg or travelerYes, AutoVolt LoZYes, AutoVolt LoZ
Prove dead before workYes, leadsYes, leads
240 V dryer or range receptacleYesYes
Continuity on a long home runYesYes
Find the live cable in a box without leadsSeparate penVoltAlert
Bath fan or disposal running ampsNoYes, in series
Ceiling fan capacitorNoYes, µF
AC condenser run capacitorNoYes, µF
Generator or inverter frequencyNoYes

The 114 covers the first five rows, the work that fills an install day. The 117 covers all ten, and the bottom five are what a service electrician meets on call-backs: a disposal that hums, a fan that runs slow on a weak capacitor, a homeowner's standby generator. For long runs, our guide to continuity on a long electrical wire works with either meter.

Which should you buy?

You are…Better fitWhy
Residential service electricianFluke 117Amps, capacitance and VoltAlert for call-backs
New-construction installerFluke 114Voltage, continuity and LoZ cover rough-in and trim-out
Apprentice buying a first meterFluke 117One meter that covers every task you'll be handed
Electrician who carries a clamp and penFluke 114The 117's extras would duplicate your other tools
Remodel and old-house specialistEitherBoth have LoZ for mixed old and new wiring
Electrician who also does light HVACFluke 117Run capacitors and motor amps

If you are weighing the 114 against the general-purpose model instead, our Fluke 114 vs Fluke 115 page sets out that trade, and Fluke 115 vs Fluke 117 shows what LoZ and VoltAlert add to the 115. Need CAT IV for service entrances? Compare Fluke 117 vs Fluke 87V, or browse the best multimeter for electricians guide.

Notes on Fluke's published specs

Source conflicts we found

Fluke's 114 product page says in its overview that the meter shows True RMS "voltage and current", but its specification table lists no current ranges and the meter has only two jacks, so we treat it as having no current function. Fluke lists the 114 at 550 g, while the Amazon listing says 0.51 kg. For the 117, Fluke's 2020 manual lists a 99.99 kHz frequency range that the datasheet's 50.00 kHz top range does not show.

Safety: CAT III means panels and branch circuits, not the meter base

Both meters are rated CAT III 600V, which covers a home's panel, feeders and branch circuits. Neither is rated CAT IV, so neither belongs on the line side of the meter base or the service drop. VoltAlert silence on the 117 is not proof of dead: shielded cable and deep boxes can hide a live conductor, and it can't sense DC. Verify with the leads on a known live source before and after testing, and follow your lockout procedure.

Choose the Fluke 114 if…

  • ✓Your work is new construction rough-in and trim-out, where voltage and continuity are nearly every check
  • ✓You already carry a non-contact pen and a clamp meter
  • ✓You want the simplest dial in the 110 Series with LoZ included

Choose the Fluke 117 if…

  • ✓You do service calls where the next problem could be a dead outlet, a tripping breaker or a hot motor
  • ✓You want non-contact detection on the meter instead of a separate pen
  • ✓You test bath fans, disposals, ceiling fan capacitors or AC run capacitors

The bottom line

Residential service electricians should buy the Fluke 117: it keeps the 114's AutoVolt ghost-voltage check and adds VoltAlert, 10 A current and capacitance for the call-backs that go beyond voltage. The Fluke 114 is the better fit for new-construction installers who already carry a pen tester and clamp meter and want the simplest dial with LoZ.

Frequently asked questions

Do both the Fluke 114 and 117 have LoZ?+

Yes. Both have the AUTO-V LoZ position, which lowers the input impedance to drain ghost voltage and picks AC or DC automatically, on a 600.0 V range at ±(2.0% + 3). For a residential electrician sorting phantom readings on travelers and abandoned cable, the two meters behave the same. The 115 is the 110 Series model without it.

Does the Fluke 114 have non-contact voltage detection?+

No. VoltAlert is a 117 feature in the 110 Series. On the 117 it sits in the top edge of the meter, with Lo and Hi sensitivity settings. With a 114 you would carry a separate non-contact pen tester. In both cases, a non-contact check is a first step, not proof that a conductor is dead.

Can the Fluke 117 measure a garbage disposal's current?+

Usually, if its nameplate current is under 10 A at 120 V, which puts it inside the 117's 10.00 A range. You must break the circuit and wire the meter in series through its A jack. The 114 has no current function at all. For higher loads or quick checks without opening the circuit, a clamp meter is easier and safer.

Is the Fluke 114 good enough for a residential electrician?+

For installation work, yes. Rough-in and trim-out mostly need voltage, continuity and resistance, and the 114 has AutoVolt LoZ to stop phantom readings fooling you. It falls short on service calls that need motor current, capacitor checks or frequency, which the 117 adds. Many installers pair a 114 with a clamp meter instead.

Can I use the Fluke 114 or 117 on a GFCI outlet?+

Yes, with one precaution. Normal voltage readings are fine on either meter. AutoVolt uses a low-impedance input, and Fluke warns, for its 113 LoZ meter, that phase-to-earth LoZ checks can trip a GFCI or RCD. Measure hot to ground on the normal V AC position, or hot to neutral on AutoVolt, to avoid nuisance trips.

Are the Fluke 114 and 117 safe to use in a residential panel?+

Both are rated CAT III 600V, which covers distribution panels, feeders and branch circuits in a home. Neither is rated CAT IV, so don't use either on the line side of the meter base or at the service drop. Use leads in good condition with tip guards fitted, and prove dead with a live-dead-live test.