COMPARISON · MULTIMETERS

Fluke 116 vs Fluke 117: Which Is Better for Electricians?

For most electricians the Fluke 117 is the better meter: it has VoltAlert non-contact detection and 6 A and 10 A current ranges, and the Fluke 116 has neither. The 116 is Fluke's HVAC model, trading the amp ranges for a 600.0 µA range and a thermocouple input. Both share the same case, CAT III 600V rating, True RMS core and AutoVolt LoZ input, so this Fluke 116 vs Fluke 117 comparison comes down to amps and NCV against microamps and temperature.

By the OhmSavvy Research Team ·

Disclosure: OhmSavvy earns a commission from qualifying Amazon purchases made through these links, at no extra cost to you. How we're funded.

Fluke 117 electrician's True RMS multimeter with VoltAlert, front view
Best OverallHands-on Tested

Fluke 117

4.8★★★★★

The meter working electricians actually buy with their own money, not just the one brands push.

Fluke 116 HVAC True RMS multimeter, front view
Best HVAC Multimeter

Fluke 116

4.6★★★★★

Fluke's HVAC multimeter: a 0.1 µA flame-sensor range, temperature, capacitance and LoZ in a CAT III 600V body.

Specs side by side

Fluke 117Fluke 116
Rating4.8★★★★★4.6★★★★★
AccuracyTrue RMSTrue RMS
Safety ratingCAT III 600VCAT III 600V
Auto-ranging YesNot stated by Fluke (manual RANGE button)
Best forElectricians, serious hobbyistsHVAC flame sensors, capacitors, controls
VoltAlert non-contact voltageYes, Lo/Hi sensitivity No
AutoVolt with LoZ inputYes, about 3 kΩYes, about 3 kΩ
Current ranges6.000 A and 10.00 A AC/DC600.0 µA AC/DC only
Finest current step1 mA0.1 µA
Temperature No-40 to 400 °C, Type K (80BK probe included)
Capacitance1 nF to 9,999 µF1 nF to 9,999 µF
ResistanceTo 40.00 MΩTo 40.00 MΩ
FrequencyTo 50.00 kHzTo 50.00 kHz
Display6,000 counts + 33-segment bar graph6,000 counts + 33-segment bar graph
Size / weight167 × 84 × 46 mm, 550 g167 × 84 × 46 mm, 550 g
BatteryOne 9V, 400 h typicalOne 9V, 400 h typical
Warranty3 years3 years

Specs checked against manufacturer documentation and official Amazon listings. Fluke 117 is hands-on tested by OhmSavvy; the Fluke 116 assessment is desk research. How we research.

Key differences

  • →The 117 has VoltAlert, a sensor in the top of the case that flags a live AC conductor without contact. Fluke's 116 page and datasheet list no non-contact detection for the 116.
  • →The 117 reads current on 6.000 A and 10.00 A ranges through its A jack. The 116 has no amp or milliamp range at all; its only current range is 600.0 µA.
  • →The 116 reads microamps to 0.1 µA, which is what furnace flame-rod checks need. The 117's finest current step is 1 mA, ten thousand times coarser.
  • →The 116 reads Type K temperature from -40 to 400 °C and ships with an 80BK probe. The 117 has no temperature function.
  • →Both have AutoVolt with a roughly 3 kΩ LoZ input for ghost voltage, both are True RMS and CAT III 600V, and both share the same case, display, battery and 3-year warranty.

The short version

Shared core

True RMS volts, CAT III 600V, 6,000 counts, AutoVolt LoZ, capacitance, frequency.

117 only

VoltAlert NCV and 6 A / 10 A current through the leads.

116 only

600.0 µA range at 0.1 µA and a Type K thermocouple input.

For electricians

The 117. Amps and NCV come up every day; microamps rarely do.

For HVAC crossover

The 116, paired with a clamp meter for motor and compressor amps.

Our testing

The 117 is owner-tested; the 116 is desk research on Fluke specs.

These two sit side by side in Fluke's 110 Series and look almost identical in a tool bag. The difference is in the dial and the input jacks: Fluke built the 117 around building wiring and the 116 around gas heating equipment. The 117 carries our Hands-on Tested badge; for the 116 we rely on Fluke's product page, its datasheet and the 110 Series manual. If you are weighing the 117 against the model without the electrician extras instead, our Fluke 115 vs Fluke 117 page covers that pair.

Fluke 116 vs 117 spec by spec

On voltage, resistance, capacitance and frequency, Fluke publishes the same accuracy lines for both meters. The rows that change are all about current, temperature and non-contact sensing.

SpecFluke 117Fluke 116Same?
DC volts600.0 mV to 600.0 V, ±(0.5% + 2)600.0 mV to 600.0 V, ±(0.5% + 2)Same
AC volts, True RMSTo 600.0 V, ±(1.0% + 3), 45–500 HzTo 600.0 V, ±(1.0% + 3), 45–500 HzSame
AutoVolt (LoZ)600.0 V, ±(2.0% + 3)600.0 V, ±(2.0% + 3)Same
VoltAlert NCVYesNo117 only
Amps AC/DC6.000 A and 10.00 ANone117 only
Microamps AC/DCNone600.0 µA, 0.1 µA steps116 only
DC µA accuracyNot applicable±(1.0% + 2)116 only
TemperatureNone-40 to 400 °C, ±(1% + 10)116 only
Resistance600.0 Ω to 40.00 MΩ600.0 Ω to 40.00 MΩSame
ContinuityBeeps below 20 ΩBeeps below 20 ΩSame
Capacitance1 nF to 9,999 µF, ±(1.9% + 2)1 nF to 9,999 µF, ±(1.9% + 2)Same
FrequencyTo 50.00 kHz, ±(0.1% + 2)To 50.00 kHz, ±(0.1% + 2)Same
Min/Max/Avg, backlightYesYesSame
Safety ratingCAT III 600VCAT III 600VSame
In the box, beyond leadsHolsterHolster and 80BK temperature probeDiffers
Fluke 117 (A jack)
10.00 A
Fluke 116 (µA jack)
600.0 µA

Bars use a logarithmic scale: each step is ten times the last.

Highest current each meter accepts on its current input, log scale. The 117 also tolerates 20 A for 30 seconds.
Fluke 117
1 mA (1,000 µA)
Fluke 116
0.1 µA

Bars use a logarithmic scale: each step is ten times the last.

Smallest current step each meter can show, in microamps, log scale. Smaller is finer.

Put those two charts together and the meters barely overlap. The 116's current input tops out at 0.0006 A, which is below the 117's smallest displayed step of 0.001 A. One reads tiny control-circuit currents, the other reads loads.

What each current input can see

The diagram below puts both current ranges on one logarithmic axis and marks three currents an electrician meets. A flame rod sits a few microamps from zero, inside the 116's window and invisible to the 117. A 4–20 mA process loop sits in the gap between them: it overloads the 116, and on the 117 a 12 mA reading shows as 0.012 A with ±(1.0% + 3) DC accuracy, roughly ±3 mA, too coarse to calibrate a transmitter. A loaded 15 A branch circuit sits past the 117's 10.00 A continuous limit.

0.1µA1µA100µA1mA100mA10AFluke 116: 600.0 µA rangeFluke 117: 6 A / 10 A (1 mA steps)flame rod4–20 mA loop15 A circuitLog scale: each labeled step is 10× or 100× the one beforeWhich currents each meter can actually resolve
Current coverage of the 116 and 117 on a log axis. Marked currents are typical values, not Fluke figures.

The practical lesson is that neither meter is the right amp tool for most electrical work. Branch-circuit and motor currents belong to a clamp meter, and loop currents to a meter with a real milliamp range; our 4–20 mA loop testing guide lists those. The 117's amp ranges still earn their place for small loads, such as a bathroom fan, a doorbell transformer or a low-voltage lighting run. The 116 cannot take those readings at all.

The electrician's day with each meter

Picture a service call for a dead kitchen circuit. With the 117, you sweep the receptacles with VoltAlert to find the last live box, switch to AutoVolt to see whether the 40-odd volts on the dead leg is coupling or a loose neutral, prove dead with the leads, then check continuity on the pigtails. The 116 does every step except the first: AutoVolt and LoZ are on its dial too, so ghost voltage fools neither meter. Without VoltAlert, the 116 owner touches leads to each box or pulls a pen tester from a pocket.

Next comes a lighting retrofit where you want to confirm a fixture draws what its label says. The 117 reads it in series on the 6.000 A range. The 116 can't, so you clamp it with a second tool. Then a rooftop unit won't fire. Here the 116 pulls ahead: it reads the flame-rod microamps and the supply-air temperature with the included probe, where the 117 can only confirm 24 V at the gas valve.

Electrical taskFluke 117Fluke 116
Find a live box or cordVoltAlert, no contactLeads or a separate pen
Ghost voltage on a dead legAutoVolt LoZAutoVolt LoZ
Prove dead before workLeads, live-dead-liveLeads, live-dead-live
Small load current (under 10 A)In series on the A jackNot possible
Branch-circuit or motor ampsClamp meterClamp meter
Run or start capacitorCapacitance, to 9,999 µFCapacitance, to 9,999 µF
Furnace flame sensorCan't resolve µA600.0 µA at 0.1 µA
Supply or return air temperatureNoType K, 80BK probe

Count the rows. On wiring work, the 117 wins two and ties the rest. On heating equipment, the 116 wins two and the 117 wins none. That split is the whole decision for a mixed contractor: whichever kind of call fills more of your week decides the meter on your belt, and the other job gets a second tool. For an all-electrical shortlist, see the best multimeter for electricians; for the heating side, the best multimeter for HVAC technicians.

Why VoltAlert matters more than it sounds

VoltAlert is a capacitive sensor at the top of the 117. Fluke gives it two sensitivities: Lo for flush receptacles, power strips and cords, and Hi for recessed sockets and bare conductors from 24 V. Its value for an electrician isn't precision; it is speed and habit. You check every box you open before your hands go in, without unholstering the leads. On the 116 that check needs a separate non-contact tester, and a second tool is one more thing to leave in the truck.

LoZ is a tie, not a tiebreaker

Some buyers assume the electrician's model has features the HVAC model lacks across the board. On ghost voltage it doesn't: Fluke lists AutoVolt with a low-impedance input of about 3 kΩ on both the 116 and the 117, with the same ±(2.0% + 3) accuracy on the 600.0 V range. That matters on long thermostat cables as much as on shared conduit. The meter that lacks LoZ in this family is the 115. For how phantom voltage forms, read our guide to measuring voltage on a floating circuit.

Where the 116 earns a place in an electrician's bag

Electricians who also service residential heating, or who work in facilities where boilers and air handlers are part of the job, run into the two readings only the 116 can take. A gas furnace that lights and then shuts down within seconds often points to a weak flame signal, and the only way to see it is a microamp reading in series with the flame rod. Our guide to measuring microamps walks through the hookup. Temperature checks on supply air or a pipe are the other job, and the 116 ships with the 80BK probe to do them.

What you give up is the A jack. The only current range Fluke lists for the 116 is the 600.0 µA one, so every amp reading on that kit goes to a clamp. Many HVAC technicians carry exactly that pair. An electrician who reads small loads in series most weeks will miss the 117's 10 A range more than they gain from microamps. If you want temperature without losing amps, the Fluke 117 vs Fluke 179 page covers a Fluke that has both.

Fluke 116 vs 117 for HVAC work

Swap the electrician for an HVAC technician and the scorecard changes, though less than you might expect. Both meters share several readings HVAC calls depend on: run-capacitor microfarads (1 nF to 9,999 µF at ±(1.9% + 2) on each), 24 V control voltage with a LoZ position for idle thermostat conductors, and pilot thermocouple millivolts on the same 600.0 mV DC range. What splits them is the season. A heating call leans on the 116's microamps and Type K input; the 117 answers with VoltAlert at the condenser disconnect and a 6.000 A range that reads heat-anticipator and other small control currents in series.

HVAC readingCall typeFluke 116Fluke 117
Flame-rod signal, a few µAHeating600.0 µA range, 0.1 µA stepsReads 0.000 A
Temperature rise across the furnaceHeatingType K, 80BK probe includedNo temperature input
Pilot thermocouple millivoltsHeating600.0 mV DC600.0 mV DC
Heat-anticipator current, under 1 AHeatingNot possible6.000 A range, 1 mA steps
Run capacitor on the condenserCoolingTo 9,999 µF, ±(1.9% + 2)To 9,999 µF, ±(1.9% + 2)
Supply vs return air splitCoolingType K, 0.1 °C stepsNo temperature input
Is the disconnect still live?CoolingLeads onlyVoltAlert first, then leads
Thermostat or 24 V transformerBothV AC or AutoVolt LoZV AC or AutoVolt LoZ
Compressor or blower ampsBothClamp meterClamp meter
116, heating rows
3 of 4
117, heating rows
2 of 4
116, cooling rows
2 of 3
117, cooling rows
2 of 3
Heating-only and cooling-only rows from the table that each meter handles on its own. The two shared rows are left out.

Cooling work is a draw: each meter misses one reading the other takes. Heating work tips to the 116, because a furnace that lights and drops out can't be diagnosed without a microamp range, while the anticipator check the 117 wins applies only to older mechanical thermostats. An HVAC technician with gas furnaces on the route should carry the 116 plus a clamp; one working on heat pumps and mini-splits loses little with the 117 and gains a non-contact check before opening a condenser panel. The heating-side detail, including the flame-rod hookup and temperature tolerances, is on our Fluke 116 vs Fluke 115 for HVAC page rather than repeated here.

Fluke 116 vs Fluke 117: which should you buy?

You are…Better fitWhy
Residential or commercial electricianFluke 117VoltAlert and the 10 A range get used daily
Electrical apprenticeFluke 117Built-in NCV reinforces checking every box before touching
HVAC technicianFluke 116Flame-rod µA and temperature; pair with a clamp for amps
Electrician who also services furnacesFluke 116 + clampCovers the readings the 117 can't, LoZ included
Facilities or maintenance techDepends on the callsWiring faults favor the 117; boilers and air handlers the 116
Controls or instrumentation techNeither alone4–20 mA loops need a true milliamp range
HomeownerFluke 117NCV and amps are more useful than microamps around the house

Read our Fluke 117 review for the owner-tested view of the electrician's model, or the best multimeters roundup for meters outside the 110 Series.

Safety: both meters stop at CAT III 600V

The 116 and 117 are rated CAT III 600V, which covers panels, feeders and branch circuits but not the meter base, service drop or outdoor service conductors, where CAT IV applies. VoltAlert can miss a live conductor in shielded cable and cannot sense DC, so treat silence as "not proven" and confirm dead with the leads on a known live source before and after. Never clip a thermocouple probe to an energized part, and never put either meter in series with a circuit that could exceed its current input; the 116's µA jack is for flame and control circuits only. If you're not qualified for live work, call a licensed electrician.

Choose the Fluke 117 if…

  • ✓You wire and troubleshoot branch circuits, receptacles, lighting and panels
  • ✓You want a non-contact voltage sensor built into the meter you already carry
  • ✓You need to read load current through the leads, up to 10 A

Choose the Fluke 116 if…

  • ✓Your electrical work leans toward furnaces, boilers and HVAC controls
  • ✓You need to read flame-sensor microamps and thermocouple temperature
  • ✓You already carry a clamp meter for every amp reading

The bottom line

Electricians should buy the Fluke 117: VoltAlert and the 6 A and 10 A ranges serve wiring work every day, and it shares the 116's LoZ input, True RMS core and CAT III 600V rating. Buy the Fluke 116 only if furnaces, boilers or HVAC controls make up a real share of your calls, and carry a clamp meter with it for amps.

Frequently asked questions

What is the main difference between the Fluke 116 and 117?+

The 117 is built for electricians: it adds VoltAlert non-contact detection and 6 A and 10 A current ranges. The 116 is built for HVAC: it swaps those for a 600.0 µA range at 0.1 µA and a Type K temperature input, with an 80BK probe in the box. Voltage, resistance, capacitance, LoZ and the case are shared.

Does the Fluke 116 have non-contact voltage detection?+

No. Fluke's 116 product page and the 110 Series datasheet list VoltAlert only on the Fluke 117. If you carry a 116 for wiring work, add a separate non-contact pen tester for quick checks, and still prove circuits dead with the test leads before touching anything.

Can the Fluke 116 measure amps?+

Only microamps. Its single current input reads up to 600.0 µA AC or DC with 0.1 µA resolution, which suits flame sensors and small control currents. There is no milliamp or amp range, so motor, compressor or appliance current needs a clamp meter. The 117 reads up to 10 A through its A jack.

Do both the Fluke 116 and 117 have LoZ?+

Yes. Both have an AutoVolt dial position that selects AC or DC automatically and drops the input to about 3 kΩ, which drains capacitively coupled ghost voltage. Fluke gives the same ±(2.0% + 3) accuracy on its 600.0 V range for both. In the 110 Series, the 115 is the model without LoZ.

Can an electrician use the Fluke 116 instead of the 117?+

Yes, for voltage, resistance, continuity, capacitance and ghost-voltage checks, since those functions match the 117. You lose built-in non-contact detection and any way to read load current through the leads. Electricians who already carry a clamp meter and a pen tester can manage, but most are better served by the 117.

Can the Fluke 117 test a furnace flame sensor?+

Not usefully. Flame-sensor current is typically a few microamps, and the 117's finest current step is 1 mA, so the display reads zero. Fluke designed the 116 for this job with its 600.0 µA range at 0.1 µA resolution. HVAC clamp meters with a µA range, such as the Klein CL445, also do it.

Is the Fluke 116 or 117 better for HVAC?+

For technicians who service gas furnaces, the 116: it reads flame-rod current to 0.1 µA and Type K temperature with the included 80BK probe, and the 117 can do neither. On cooling calls the two are close, since both test run capacitors and have LoZ for 24 V controls. Carry a clamp meter with either for compressor and blower amps.

Are the Fluke 116 and 117 the same size?+

Yes. Fluke lists both at 167 × 84 × 46 mm and 550 g, running on one 9V battery with about 400 hours of typical life without the backlight. Both carry a 3-year warranty and the same CAT III 600V rating, so holsters, hangers and accessories for one fit the other.