Fluke 1587 FC vs Fluke 287: Which Is Better for Electrical Diagnostics?

In this Fluke 1587 FC vs 287 comparison, the deciding question is whether your faults are found with the power on or with it off. The 1587 FC is the one to buy when you need to prove motor windings and cables are sound: it applies 50 to 1000 V and reads insulation up to 2 GΩ. The 287 is the one to buy when you need to watch a running circuit misbehave: it records for hours at 50,000 counts and measures from 0.01 µA up to 10 A. Both carry the same CAT IV 600V / CAT III 1000V rating, and we have not hands-on tested either.

By the OhmSavvy Research Team ·

Disclosure: OhmSavvy earns a commission from qualifying Amazon purchases made through these links, at no extra cost to you. How we're funded.

Fluke 1587 FC insulation multimeter with the yellow insulation test key and Fluke Connect save button
Best Insulation Multimeter

Fluke 1587 FC

4.6★★★★★

A True RMS multimeter and 50–1000 V insulation tester in one, with PI/DAR tests and Fluke Connect logging to your phone.

Fluke 287 logging multimeter showing its graphical trend display
Best Logging Meter for Electronics

Fluke 287

4.6★★★★★

Fluke's electronics logging meter: 50,000 counts, 0.01 µA resolution and graphs on the meter, without the 289's industrial extras.

Specs side by side

Fluke 1587 FCFluke 287
Rating4.6★★★★★4.6★★★★★
AccuracyTrue RMS, ±(0.09% + 2) DC VTrue RMS, 0.025% basic DC V
Safety ratingCAT IV 600V / CAT III 1000VCAT IV 600V / CAT III 1000V
Auto-rangingYes (manual override)Yes (manual override)
Best forMotor, cable and insulation testingElectronics design, µA and logging
Display6,000 counts50,000 counts with graphics
Insulation test50, 100, 250, 500, 1000 V; to 2 GΩNone
DC volts accuracy (best)±(0.09% + 2)±(0.025% + 2)
AC volts accuracy±(1% + 3) at 50–60 Hz±(0.3% + 25) at 45–65 Hz
Low-pass filter YesNo (289 only)
Current60 mA and 400 mA ranges only0.01 µA resolution up to 10 A (20 A for 30 s)
Resistance (meter)0.1 Ω to 50 MΩ0.01 Ω to 500 MΩ
CapacitanceTo 9,999 µF1 nF to 100 mF
FrequencyTo 99.99 kHz0.5 Hz to 999.99 kHz, plus duty cycle
Temperature-40 to 537 °C, K-type included-200 to 1350 °C (probe excluded)
RecordingTo the Fluke Connect appUp to 10,000 intervals in the meter
Data link2.4 GHz radio to phone or tabletIR cable to FlukeView Forms on a PC
Safety ratingCAT IV 600V / CAT III 1000VCAT IV 600V / CAT III 1000V
Battery4 × AA; 1000 h, 1000+ insulation tests6 × AA; 100 h min, 200 h logging
Weight550 g (Amazon lists 1645 g)871 g
Warranty3 yearsLifetime limited

Specs checked against manufacturer documentation and official Amazon listings. Desk research, not bench testing. How we research.

Key differences

  • →Only the 1587 FC can stress insulation with a test voltage (50 to 1000 V) and report megohms and gigohms; the 287 has no insulation function.
  • →The 287 records unattended in its own memory with a real-time clock and graphs the trend on screen; the 1587 FC sends its readings and PI/DAR graphs to the Fluke Connect app instead.
  • →Current is lopsided: the 287 covers 0.01 µA resolution through 10 A, while the 1587 FC stops at 400 mA with no 10 A jack.
  • →The 287 resolves finer: 50,000 counts and ±(0.025% + 2) DC volts against 6,000 counts and ±(0.09% + 2).
  • →The 1587 FC has a low-pass filter for drive outputs; the 287 does not (Fluke reserves that for the 289).
  • →Safety category is identical: both are CAT IV 600V / CAT III 1000V.

Power on or power off: where each meter enters a diagnosis

Most electrical diagnoses have two halves. While equipment is running you collect symptoms: a voltage that sags when a compressor starts, a current that creeps up over a shift, a control signal that drops out once an hour. After you shut it down and lock it out, you confirm a cause: a winding that has absorbed moisture, a cable whose jacket has cracked, a terminal that has tracked to ground. The 287 is designed for the first half. The 1587 FC is designed for the second.

  1. 01

    Record supply

    287 logs volts at the starter for a shift

  2. 02

    Check load

    287 reads current in series to 10 A

  3. 03

    Isolate

    Lock out, tag out, verify dead

  4. 04

    Insulation test

    1587 FC at 500 or 1000 V

  5. 05

    Trend it

    1587 FC PI/DAR saved in the app

A general motor-fault sequence (illustrative workflow, not a test we ran). Steps 1 and 2 suit the 287; steps 4 and 5 need the 1587 FC.

That split explains almost every spec difference below. An insulation tester must hold steady test voltage into a cable and then discharge it safely, so the 1587 FC spends its design budget there and keeps the meter side to 6,000 counts and milliamps. A logging meter must sit on a live panel for a long time and capture what happens, so the 287 spends its budget on a large graphic screen, deep memory, six AA cells and a wide current range. If your work regularly includes both halves, the honest answer is that you will eventually own both kinds of instrument.

The numbers side by side

Fluke 1587 FC
6,000
Fluke 287
50,000

Bars use a logarithmic scale: each step is ten times the last.

Display resolution, log scale. The 287 shows about eight times as many counts.
Fluke 1587 FC
0.4 A
Fluke 287
10 A
Highest current measured through the meter's own jacks.
1587 FC ohms
50 MΩ
287 ohms
500 MΩ
1587 FC insulation
2 GΩ

Bars use a logarithmic scale: each step is ten times the last.

Highest resistance each can report, log scale. Only the 1587 FC gets there with a high test voltage.
Fluke 1587 FC
99.99 kHz
Fluke 287
999.99 kHz

Bars use a logarithmic scale: each step is ten times the last.

Top of the frequency range, log scale.

The resistance chart needs a caution. The 287's 500 MΩ range can look like an insulation reading, but it comes from the ordinary ohms circuit, which drives only a small voltage through the part. A winding with damp or contaminated insulation can look fine at that level and still break down when a few hundred volts are applied, which is the condition a motor sees in service. That is the gap the 1587 FC's 250, 500 and 1000 V test positions close. Fluke publishes the 287's high-ohm range, not a test voltage for it, so treat it as a continuity-class check, not proof of insulation.

Current measurement shapes the toolkit

On the 287 you can put the meter in series with a load up to 10 A, read a 4–20 mA loop on the 50 mA range at 0.001 mA steps, or drop to the 500 µA range for a standby drain at 0.01 µA. Fluke publishes the burden on that microamp range as 102 µV per µA, so you can work out how much the meter itself disturbs a low-voltage circuit. With logging switched on, the same current ranges can record a compressor's draw across a whole cycle.

The 1587 FC offers just two current ranges, 60 mA and 400 mA, protected by a 0.44 A fuse. That covers control circuits and sensor loops, not motor current. Kits that bundle the 1587 FC with Fluke's i400 current clamp are separate Amazon listings; the one we link is the bare meter. If running current is part of most of your calls, pair the 1587 FC with a clamp meter (our clamp meter buying guide covers the choice) or look at a 10 A meter.

Two kinds of record keeping

Both meters let you keep evidence, but the evidence looks different. The 287 writes interval and event records into its own memory, stamped by a real-time clock, and draws them as a TrendCapture graph you can scroll and zoom on the meter. Fluke's manual sets the ceiling at 10,000 sample intervals, with event records sharing a 15,000 total; Fluke's product page words it two ways ("up to 10,000 readings" and "up to 15,000 recorded events"), which matches the manual's split between intervals and events. Full records leave the meter over an IR cable into FlukeView Forms on a PC.

The 1587 FC keeps its history in the Fluke Connect app over a 2.4 GHz radio. What it stores is less about minute-by-minute behavior and more about asset condition: a 1-minute insulation value, a PI or DAR ratio with its TrendIt graph, and the same test repeated next quarter with temperature compensation so a cold morning and a hot afternoon can be compared fairly. That is maintenance-history data. For what PI and DAR mean and how to read them, see Fluke 1587 FC vs Fluke 87V; for the 287's event records on an intermittent fault, see Fluke 287 vs Fluke 87V.

A useful way to decide

Ask what you need to show someone afterward. If it is "here is what the supply did at 2:14 a.m.," that is a 287 record. If it is "this motor's insulation has fallen since the last inspection," that is a 1587 FC record.

Live diagnostics on drives and electronics

One result surprises people. On a variable-frequency drive output, the insulation meter is the one with the better tool: a low-pass filter that blocks the high-frequency switching so the voltmeter shows the fundamental the motor responds to. Fluke's 287/289 manual lists that filter as "Model 289 only," so the 287 has none, and neither has LoZ. If you troubleshoot drive-fed motors and also want logging, the Fluke 289 vs Fluke 287 page explains what the extra money buys.

On control boards and instrumentation, the 287 pulls well ahead: 0.01 Ω steps on its 500 Ω range, capacitance from 1 nF to 100 mF, duty cycle and frequency to 999.99 kHz, and a 250 µs peak capture for brief spikes. The 1587 FC covers capacitance to 9,999 µF and frequency to 99.99 kHz, which handles motor-run capacitors and line frequency but not much finer electronics work. Temperature favors the 1587 FC in one way: Fluke includes a K-type thermocouple, while our sources don't state that the 287 ships with one.

Which should you buy?

Diagnostic taskBetter fitWhy
Motor that trips its overload after rewindingFluke 1587 FCInsulation test to 1000 V, PI/DAR
Cable that may have been damaged by waterFluke 1587 FCMegohm readings at service-like voltage
Voltage sag that appears once a nightFluke 287Time-stamped log, on-screen trend
Load current on a 120 V branch deviceFluke 28710 A input; 1587 FC stops at 400 mA
Standby drain on a control boardFluke 2870.01 µA resolution
Voltage at a VFD output terminalFluke 1587 FCLow-pass filter; 287 has none
Quarterly insulation checks on the same assetsFluke 1587 FCApp history with temperature compensation
One meter for a mixed plant and bench jobDependsNeither covers the other's specialty

If insulation testing is the main reason you are shopping and you only need 500 V and 1000 V, the Fluke 1577 vs Fluke 1587 FC comparison covers the simpler model. If you work outdoors or in wet plants, read Fluke 1587 FC vs Fluke 87V MAX, since the 1587 FC is only IP40. For a broader list of meters by trade, see the best multimeters for electricians and our guide to checking a motor winding for a short.

Safety: insulation tests put high voltage on the circuit

The 1587 FC can drive up to 1000 V DC into whatever you connect it to. Only qualified, trained personnel should run an insulation test. Before you start, de-energize the equipment, apply lockout/tagout, and verify absence of voltage with a known-good meter tested on a live source before and after. Disconnect drives, surge protectors and electronics that the test voltage could damage. Keep hands and other people clear of the conductors while the test runs. Afterward, let the meter discharge the circuit and confirm it reads zero before touching anything: long cables and large windings store charge. The 1587 FC refuses to start a test above 30 V, but that is a backstop, not a substitute for isolation. When you leave the 287 logging inside a live panel, keep the door closed, route leads so they are not pinched, and follow your site's arc-flash rules. If you are not trained for this work, call a licensed electrician.

Choose the Fluke 1587 FC if…

  • ✓Your repairs end with the question "is this winding or cable still insulated?"
  • ✓You want PI and DAR results, with temperature compensation, stored in an app
  • ✓You troubleshoot VFD-fed motors and need a low-pass filter on AC volts

Choose the Fluke 287 if…

  • ✓You chase faults that come and go, and need a time-stamped record of them
  • ✓You measure load current in series up to 10 A, or sleep current in microamps
  • ✓You want 50,000-count resolution and frequency readings to 999.99 kHz

The bottom line

Buy the Fluke 1587 FC if your diagnoses end at the insulation question, especially on motors, cables and drive-fed equipment; its 50 to 1000 V tests, PI/DAR and low-pass filter suit maintenance electricians. Buy the Fluke 287 if your diagnoses depend on watching a live circuit over time, measuring real load or microamp current, or resolving small changes at 50,000 counts. They overlap only in basic volts and ohms, so for many plants the right answer is one of each.

Frequently asked questions

Can the Fluke 287 test insulation resistance?+

No. The 287 has no insulation test function. Its 500 MΩ resistance range uses the ordinary ohms circuit and Fluke doesn't publish a test voltage for it, so it can't show how insulation behaves under the hundreds of volts it sees in service. For that you need an insulation tester such as the 1587 FC, which applies 50 to 1000 V.

Can the Fluke 1587 FC measure motor running current?+

Not directly in most cases. Its current inputs have 60 mA and 400 mA ranges only, with a 0.44 A fuse and no 10 A jack. That suits control circuits and sensor loops. For motor current, use a clamp meter or a kit that bundles the 1587 FC with Fluke's i400 clamp, sold as a separate Amazon listing; the one we link is the bare meter.

Which is more accurate, the Fluke 1587 FC or the 287?+

The 287, on Fluke's published specs. Its best DC volts accuracy is ±(0.025% + 2) on a 50,000-count display, against ±(0.09% + 2) on 6,000 counts for the 1587 FC. On AC volts the 287 lists ±(0.3% + 25) at 45 to 65 Hz, while the 1587 FC lists ±(1% + 3) at 50 to 60 Hz.

Does the Fluke 287 work with the Fluke Connect app?+

Not according to our sources. The 287 transfers its records over an IR optical cable to FlukeView Forms software on a PC, and Fluke doesn't list a wireless link. The 1587 FC is the Fluke Connect model of the two: it sends readings, insulation results and PI/DAR graphs to a phone or tablet over a 2.4 GHz radio.

Does the Fluke 287 have a low-pass filter for VFDs?+

No. Fluke's 287/289 manual marks the low-pass filter, LoZ and the 50 Ω range as Model 289 only. The 1587 FC does have a low-pass filter, which steadies voltage readings on drive outputs. If you need both logging and a filter in one meter, the Fluke 289 is the 280 Series model that has it.

Are the Fluke 1587 FC and 287 safe for the same electrical panels?+

Yes. Fluke rates both at CAT IV 600V and CAT III 1000V, so the measurement category is identical. One listing detail to note: the 287's Amazon page uses "Category I/II" wording that conflicts with Fluke's rating, and we follow Fluke. Always check that your test leads carry the same or higher rating.