HOW-TO GUIDE

Why Does My Heat Pump Use Too Much Electricity in Cold Weather?

A heat pump using far more electricity in cold weather is partly physics and partly settings. As the outdoor air gets colder, the house loses heat faster while the heat pump moves heat less efficiently, so consumption climbs even when everything works. What turns a higher bill into a shocking one is usually auxiliary electric heat switching on more than it needs to, aggressive thermostat setbacks, frequent defrost, or an airflow or refrigerant problem. This guide separates the expected increase from the avoidable one and shows how to measure it without going near the outdoor unit's wiring.

By the OhmSavvy Research Team ·

Fieldpiece SC480 clamp meter
HVAC technicians measure a heat pump's current and power at the unit. Homeowners use an energy monitor instead. See the HVAC meter guide.

Leave the outdoor unit and air handler closed

  • Heat pumps run on 240 V circuits and contain capacitors that can stay charged after power is off. Opening the outdoor unit, the air handler or the electric heat strips, and clamp-meter readings on their wiring, are jobs for a qualified HVAC technician.
  • Refrigerant work requires certification. Never add refrigerant or open service ports yourself.
  • A burning smell from the vents when the aux heat first runs in autumn is often dust on the strips. A smell that persists, smoke, or a tripped heat-strip breaker that trips again: switch the system off and call a technician.

Why efficiency falls as it gets colder

A heat pump doesn't make heat from electricity; it uses electricity to move heat from outdoors to indoors. The ratio of heat delivered to electricity used is the coefficient of performance, or COP. In mild weather, a typical air-source unit might deliver three or more units of heat per unit of electricity. As the outdoor air gets colder, there is less heat to collect and the compressor works harder, so COP falls, often toward two or below in severe cold, depending on the model. Cold-climate units hold up better, but every air-source heat pump follows the same trend.

47 °F (8 °C)
COP ~3–4
32 °F (0 °C)
COP ~2.5–3
17 °F (-8 °C)
COP ~2–2.5
5 °F (-15 °C)
COP ~1.5–2
Electric strip heat
COP 1
Illustrative COP of an air-source heat pump at different outdoor temperatures. Your unit's published performance data gives its real figures.

At the same time, the house loses heat faster the bigger the gap between indoor and outdoor temperature. Double the gap and you roughly double the heat needed. Lower efficiency multiplied by higher demand is why a cold snap can triple or quadruple daily heating energy without anything being wrong. Below the balance point, where the heat pump alone can no longer keep up, supplementary heat covers the shortfall.

Outdoor temperature (colder to the left)coldmildbalance pointhouse heat lossheat pump capacityaux heatfills the gap
Below the balance point the heat pump can't match the house's heat loss, and auxiliary heat makes up the difference.

Symptoms and likely causes

SymptomLikely causeWhat to checkWho should fix it
Usage rises steadily as temperatures dropNormal COP decline plus higher heat lossUsage vs outdoor temperature over several daysNo fix needed; insulation helps
Big spikes every morningSetback recovery triggering aux heatThermostat schedule and recovery settingOwner settings
High usage on mild days, 'aux' or 'em heat' showingEmergency heat left on, or aux staged too earlyThermostat mode and aux lockout settingOwner; HVAC tech
Outdoor unit frosted solid, frequent defrostAirflow, sensor or refrigerant problemLook at the coil; note defrost frequencyHVAC technician
Weak, lukewarm air and long run timesDirty filter, blocked returns, low chargeFilter, return grilles, supply air temperatureOwner (filter); tech (charge)
Usage jumped this year at the same temperaturesDeveloping fault or a changed settingCompare with last winter's interval dataHVAC technician

Auxiliary and emergency heat

Most ducted heat pumps in the US include electric resistance strips in the air handler. Resistance heat has a COP of 1: every kilowatt-hour in becomes one kilowatt-hour of heat. A set of strips can draw as much power as the heat pump several times over, so a few extra hours of aux heat per day show up clearly on the bill. Auxiliary heat is meant to supplement the heat pump below the balance point and during defrost. Emergency heat is a manual mode that runs the strips without the heat pump, intended for when the outdoor unit has failed.

Check the thermostat display. If it shows emergency heat, someone switched it on, often during a cold snap, and it was never switched back. If aux heat comes on frequently on days well above the balance point, the staging may be too aggressive: many thermostats let the installer set an outdoor-temperature lockout or a delay before aux heat is allowed. Those installer settings are worth reviewing with your technician rather than changing blind.

Defrost cycles

In cold, damp weather, frost builds on the outdoor coil and blocks airflow. The heat pump clears it by briefly reversing into cooling mode, warming the coil while the outdoor fan stops. During defrost the house would get cold air, so many systems bring on the aux heat to temper it. A few short defrosts an hour in freezing fog are normal. Defrosting far more often, or failing to clear the ice, wastes energy and points to a sensor, control or refrigerant fault.

Keep the outdoor unit clear of snow drifts, leaves and anything stacked against it, and make sure meltwater can drain away rather than refreezing under the unit. You can look; don't chip ice off the coil, because the fins bend easily and the refrigerant tubing can be punctured.

Thermostat settings that cost money

Heat pumps prefer steady temperatures. A deep overnight setback means the morning recovery asks for a large temperature rise at the coldest time of day, which is exactly the condition that calls in aux heat. A thermostat configured for a furnace rather than a heat pump may stage heat wrongly. Smart thermostats sometimes ship with recovery settings that prioritize speed over efficiency. Check the equipment type in the installer menu if you are comfortable doing so, try a smaller setback or none for a week, and compare daily usage at similar temperatures. If the thermostat keeps rebooting, our guide to a smart thermostat that keeps losing power covers the wiring side.

1Safe homeowner checks

  • Filter. A clogged filter cuts airflow, raises run time and can trip the system into aux heat. Replace it on the schedule the maker recommends, more often in heavy-use months.
  • Supply and return grilles. Keep them open and unblocked by furniture or rugs. Closing rooms off doesn't save energy on most ducted systems.
  • Supply air temperature. A thermometer at a supply register near the air handler, compared with the return air, tells you how much the air is being heated. Log it with the heat pump running alone and again when aux heat engages; a technician will want both numbers.
  • Outdoor unit. From a step back, look for ice that never clears, a fan that doesn't spin when the compressor runs, or unusual noises. Note what you see and when.
  • Breakers. If the heat-strip breaker or the outdoor unit's breaker has tripped, reset it once. If it trips again, leave it off and call the technician.

2Measuring what it really uses

The most useful number is daily heating energy plotted against outdoor temperature. Your smart meter's interval data from the utility, or a whole-home energy monitor installed by an electrician, shows consumption by the hour. Many monitors can track the heat pump and the strip heat circuits separately, which reveals immediately how much of a cold day was aux heat. A thermostat runtime report, showing hours of heat pump versus aux heat, gives the same insight for free on many smart thermostats.

Gather a couple of weeks of data and compare days with similar outdoor temperatures. A steady curve is healthy. Scattered high days at mild temperatures usually trace back to settings or aux staging. A whole winter that sits above last winter at the same temperatures suggests a developing fault, such as a slow refrigerant leak, that a technician should diagnose. Reading interval data is covered in our guide to smart meter usage at night.

Clamp-meter readings on the outdoor unit's supply, the compressor or the strips are where a technician confirms the picture: running current, start-up inrush, and, with a power clamp, actual watts and power factor. Those conductors are inside the unit and the disconnect, so leave them to the professional. For how clamp measurements work in general, see measuring AC current with a clamp meter.

When to call an HVAC technician

Call a technician if aux or emergency heat runs on mild days after you have checked the thermostat mode, if the outdoor coil stays iced, if supply air is barely warmer than return air with the heat pump running, if any breaker trips repeatedly, or if this winter's usage clearly exceeds last winter's at the same temperatures. Ask them to check refrigerant charge, defrost controls, airflow and the aux heat staging, and to share the current and temperature readings they take. If the problem turns out to be the house rather than the equipment, an energy audit of insulation and air leaks is the next step. Related: lights that flicker when the AC starts.

Meters HVAC technicians use on heat pumps

Fieldpiece SC480 clamp meter
Fieldpiece SC480

Watts, power factor, inrush and temperature in one HVACR clamp. CAT IV 600V / CAT III 1000V.

Klein Tools CL445 clamp meter
Klein Tools CL445

HVAC clamp with inrush mode, temperature and a flame-sensor µA range. CAT IV 600V / CAT III 750V.

UNI-T UT181A logging multimeter
UNI-T UT181A

Measures two thermocouples at once and logs 20,000 readings, handy for supply vs return air over time.

As an Amazon Associate I earn from qualifying purchases. Prices and availability are shown on Amazon.

Frequently asked questions

How much more electricity should a heat pump use in very cold weather?

It depends on the house, the climate and the equipment, but it is normal for daily use to rise steeply as temperatures fall, because heat loss rises and efficiency drops at the same time. Compare days with similar outdoor temperatures rather than comparing winter with autumn. A sudden jump at the same temperature is the sign of a fault or a settings change.

Is it cheaper to turn the heat pump down at night?

Small setbacks are usually fine. Large ones can cost more, because recovering several degrees on a cold morning often makes the thermostat call for auxiliary heat. Many heat pump thermostats offer a smart or adaptive recovery setting that avoids this; check its documentation.

Why is steam coming off my outdoor unit?

That is usually a normal defrost cycle melting frost off the outdoor coil, and it typically lasts a few minutes. Defrost that happens very often, ice that keeps building on the coil, or a unit encased in ice is a reason to call a technician.

Does this apply to air-to-water heat pumps in Europe?

The same physics applies. An air-to-water unit also loses efficiency as outdoor air cools and as the flow temperature it has to produce rises, so a high radiator flow temperature setting raises consumption. Many have a backup immersion or inline electric heater that behaves like auxiliary strip heat.

Is it normal for a heat pump to run nonstop in very cold weather?

Often, yes. Variable-speed heat pumps are designed to run for long periods at low speed, and near or below the balance point even a single-stage unit may run continuously. Running all the time is only a concern when the house cannot hold the thermostat setting, the supply air feels lukewarm, or the thermostat shows auxiliary heat on for most of the day.